GCC Code Coverage Report


Directory: ./
Coverage: low: ≥ 0% medium: ≥ 75.0% high: ≥ 90.0%
Coverage Exec / Excl / Total
Lines: 98.8% 170 / 0 / 172
Functions: 100.0% 1 / 0 / 1
Branches: 91.1% 195 / 0 / 214

src/energyplus/ForwardTranslator/ForwardTranslateAirConditionerVariableRefrigerantFlowFluidTemperatureControlHR.cpp
Line Branch Exec Source
1 /***********************************************************************************************************************
2 * OpenStudio(R), Copyright (c) Alliance for Energy Innovation, LLC.
3 * See also https://openstudio.net/license
4 ***********************************************************************************************************************/
5
6 #include "../ForwardTranslator.hpp"
7 #include "../../model/Model.hpp"
8
9 #include "../../model/AirConditionerVariableRefrigerantFlowFluidTemperatureControlHR.hpp"
10 #include "../../model/AirConditionerVariableRefrigerantFlowFluidTemperatureControlHR_Impl.hpp"
11 #include "../../model/LoadingIndex.hpp"
12 #include "../../model/LoadingIndex_Impl.hpp"
13
14 #include "../../model/Schedule.hpp"
15 #include "../../model/Schedule_Impl.hpp"
16 #include "../../model/Node.hpp"
17 #include "../../model/Node_Impl.hpp"
18 #include "../../model/PlantLoop.hpp"
19 #include "../../model/PlantLoop_Impl.hpp"
20 #include "../../model/ThermalZone.hpp"
21 #include "../../model/ThermalZone_Impl.hpp"
22 #include "../../model/ZoneHVACTerminalUnitVariableRefrigerantFlow.hpp"
23 #include "../../model/ZoneHVACTerminalUnitVariableRefrigerantFlow_Impl.hpp"
24 #include "../../model/Curve.hpp"
25 #include "../../model/Curve_Impl.hpp"
26 #include "../../utilities/core/Logger.hpp"
27 #include "../../utilities/core/Assert.hpp"
28 #include "../../utilities/idd/IddEnums.hpp"
29 #include "../../utilities/idf/IdfExtensibleGroup.hpp"
30
31 #include <utilities/idd/IddEnums.hxx>
32 #include <utilities/idd/AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HR_FieldEnums.hxx>
33 #include <utilities/idd/ZoneTerminalUnitList_FieldEnums.hxx>
34 #include <utilities/idd/FluidProperties_Name_FieldEnums.hxx>
35
36 using namespace openstudio::model;
37
38 namespace openstudio {
39
40 namespace energyplus {
41
42 3 boost::optional<IdfObject> ForwardTranslator::translateAirConditionerVariableRefrigerantFlowFluidTemperatureControlHR(
43 model::AirConditionerVariableRefrigerantFlowFluidTemperatureControlHR& modelObject) {
44
45 // Terminals
46
1/1
✓ Branch 1 taken 3 times.
3 std::vector<ZoneHVACTerminalUnitVariableRefrigerantFlow> terminals = modelObject.terminals();
47
2/2
✓ Branch 1 taken 1 time.
✓ Branch 2 taken 2 times.
3 if (terminals.empty()) {
48
7/7
✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 7 taken 1 time.
✓ Branch 10 taken 1 time.
✓ Branch 14 taken 1 time.
✓ Branch 17 taken 1 time.
✓ Branch 20 taken 1 time.
1 LOG(Warn, modelObject.briefDescription() << " will not be translated as it has no terminals.");
49 1 return boost::none;
50 }
51
52 // Name
53 IdfObject idfObject =
54
2/2
✓ Branch 1 taken 2 times.
✓ Branch 4 taken 2 times.
2 createRegisterAndNameIdfObject(openstudio::IddObjectType::AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HR, modelObject);
55
56 // Availability Schedule Name: Optional Object, required in Model
57 {
58
1/1
✓ Branch 1 taken 2 times.
2 auto sch = modelObject.availabilitySchedule();
59
2/3
✓ Branch 1 taken 2 times.
✓ Branch 3 taken 2 times.
✗ Branch 4 not taken.
4 if (boost::optional<IdfObject> owo_ = translateAndMapModelObject(sch)) {
60
3/3
✓ Branch 1 taken 2 times.
✓ Branch 4 taken 2 times.
✓ Branch 7 taken 2 times.
2 idfObject.setString(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::AvailabilityScheduleName, owo_->nameString());
61 2 }
62 2 }
63
64 // Refrigerant Type: Optional Object
65
2/2
✓ Branch 1 taken 2 times.
✓ Branch 4 taken 2 times.
2 boost::optional<IdfObject> fluidProperties = createFluidProperties(modelObject.refrigerantType());
66
1/2
✓ Branch 0 taken 2 times.
✗ Branch 1 not taken.
2 if (fluidProperties) {
67
2/2
✓ Branch 1 taken 2 times.
✓ Branch 4 taken 2 times.
2 boost::optional<std::string> value = fluidProperties.get().getString(FluidProperties_NameFields::FluidName, true);
68
1/2
✓ Branch 0 taken 2 times.
✗ Branch 1 not taken.
2 if (value) {
69
2/2
✓ Branch 1 taken 2 times.
✓ Branch 4 taken 2 times.
2 idfObject.setString(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::RefrigerantType, value.get());
70 }
71 2 }
72
73
2/3
✓ Branch 1 taken 2 times.
✗ Branch 3 not taken.
✓ Branch 4 taken 2 times.
2 if (modelObject.isRatedEvaporativeCapacityAutosized()) {
74 ✗ idfObject.setString(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::RatedEvaporativeCapacity, "Autosize");
75 } else {
76 // Rated Evaporative Capacity: boost::optional<double>
77
2/3
✓ Branch 1 taken 2 times.
✓ Branch 3 taken 2 times.
✗ Branch 4 not taken.
4 if (boost::optional<double> _ratedEvaporativeCapacity = modelObject.ratedEvaporativeCapacity()) {
78 2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::RatedEvaporativeCapacity,
79
2/2
✓ Branch 1 taken 2 times.
✓ Branch 4 taken 2 times.
2 _ratedEvaporativeCapacity.get());
80 }
81 }
82
83 // Rated Compressor Power Per Unit of Rated Evaporative Capacity: Optional Double
84
1/1
✓ Branch 1 taken 2 times.
2 double ratedCompressorPowerPerUnitofRatedEvaporativeCapacity = modelObject.ratedCompressorPowerPerUnitofRatedEvaporativeCapacity();
85
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(
86 AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::RatedCompressorPowerPerUnitofRatedEvaporativeCapacity,
87 ratedCompressorPowerPerUnitofRatedEvaporativeCapacity);
88
89 // Minimum Outdoor Air Temperature in Cooling Only Mode: Optional Double
90
1/1
✓ Branch 1 taken 2 times.
2 double minimumOutdoorAirTemperatureinCoolingOnlyMode = modelObject.minimumOutdoorAirTemperatureinCoolingOnlyMode();
91
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::MinimumOutdoorAirTemperatureinCoolingOnlyMode,
92 minimumOutdoorAirTemperatureinCoolingOnlyMode);
93
94 // Maximum Outdoor Air Temperature in Cooling Only Mode: Optional Double
95
1/1
✓ Branch 1 taken 2 times.
2 double maximumOutdoorAirTemperatureinCoolingOnlyMode = modelObject.maximumOutdoorAirTemperatureinCoolingOnlyMode();
96
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::MaximumOutdoorAirTemperatureinCoolingOnlyMode,
97 maximumOutdoorAirTemperatureinCoolingOnlyMode);
98
99 // Minimum Outdoor Air Temperature in Heating Only Mode: Optional Double
100
1/1
✓ Branch 1 taken 2 times.
2 double minimumOutdoorAirTemperatureinHeatingOnlyMode = modelObject.minimumOutdoorAirTemperatureinHeatingOnlyMode();
101
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::MinimumOutdoorAirTemperatureinHeatingOnlyMode,
102 minimumOutdoorAirTemperatureinHeatingOnlyMode);
103
104 // Maximum Outdoor Air Temperature in Heating Only Mode: Optional Double
105
1/1
✓ Branch 1 taken 2 times.
2 double maximumOutdoorAirTemperatureinHeatingOnlyMode = modelObject.maximumOutdoorAirTemperatureinHeatingOnlyMode();
106
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::MaximumOutdoorAirTemperatureinHeatingOnlyMode,
107 maximumOutdoorAirTemperatureinHeatingOnlyMode);
108
109 // Minimum Outdoor Temperature in Heat Recovery Mode: Optional Double
110
1/1
✓ Branch 1 taken 2 times.
2 double minimumOutdoorTemperatureinHeatRecoveryMode = modelObject.minimumOutdoorTemperatureinHeatRecoveryMode();
111
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::MinimumOutdoorTemperatureinHeatRecoveryMode,
112 minimumOutdoorTemperatureinHeatRecoveryMode);
113
114 // Maximum Outdoor Temperature in Heat Recovery Mode: Optional Double
115
1/1
✓ Branch 1 taken 2 times.
2 double maximumOutdoorTemperatureinHeatRecoveryMode = modelObject.maximumOutdoorTemperatureinHeatRecoveryMode();
116
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::MaximumOutdoorTemperatureinHeatRecoveryMode,
117 maximumOutdoorTemperatureinHeatRecoveryMode);
118
119 // Refrigerant Temperature Control Algorithm for Indoor Unit: Optional String
120
1/1
✓ Branch 1 taken 2 times.
2 std::string refrigerantTemperatureControlAlgorithmforIndoorUnit = modelObject.refrigerantTemperatureControlAlgorithmforIndoorUnit();
121
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setString(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::RefrigerantTemperatureControlAlgorithmforIndoorUnit,
122 refrigerantTemperatureControlAlgorithmforIndoorUnit);
123
124 // Reference Evaporating Temperature for Indoor Unit: Optional Double
125
1/1
✓ Branch 1 taken 2 times.
2 double referenceEvaporatingTemperatureforIndoorUnit = modelObject.referenceEvaporatingTemperatureforIndoorUnit();
126
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::ReferenceEvaporatingTemperatureforIndoorUnit,
127 referenceEvaporatingTemperatureforIndoorUnit);
128
129 // Reference Condensing Temperature for Indoor Unit: Optional Double
130
1/1
✓ Branch 1 taken 2 times.
2 double referenceCondensingTemperatureforIndoorUnit = modelObject.referenceCondensingTemperatureforIndoorUnit();
131
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::ReferenceCondensingTemperatureforIndoorUnit,
132 referenceCondensingTemperatureforIndoorUnit);
133
134 // Variable Evaporating Temperature Minimum for Indoor Unit: Optional Double
135
1/1
✓ Branch 1 taken 2 times.
2 double variableEvaporatingTemperatureMinimumforIndoorUnit = modelObject.variableEvaporatingTemperatureMinimumforIndoorUnit();
136
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::VariableEvaporatingTemperatureMinimumforIndoorUnit,
137 variableEvaporatingTemperatureMinimumforIndoorUnit);
138
139 // Variable Evaporating Temperature Maximum for Indoor Unit: Optional Double
140
1/1
✓ Branch 1 taken 2 times.
2 double variableEvaporatingTemperatureMaximumforIndoorUnit = modelObject.variableEvaporatingTemperatureMaximumforIndoorUnit();
141
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::VariableEvaporatingTemperatureMaximumforIndoorUnit,
142 variableEvaporatingTemperatureMaximumforIndoorUnit);
143
144 // Variable Condensing Temperature Minimum for Indoor Unit: Optional Double
145
1/1
✓ Branch 1 taken 2 times.
2 double variableCondensingTemperatureMinimumforIndoorUnit = modelObject.variableCondensingTemperatureMinimumforIndoorUnit();
146
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::VariableCondensingTemperatureMinimumforIndoorUnit,
147 variableCondensingTemperatureMinimumforIndoorUnit);
148
149 // Variable Condensing Temperature Maximum for Indoor Unit: Optional Double
150
1/1
✓ Branch 1 taken 2 times.
2 double variableCondensingTemperatureMaximumforIndoorUnit = modelObject.variableCondensingTemperatureMaximumforIndoorUnit();
151
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::VariableCondensingTemperatureMaximumforIndoorUnit,
152 variableCondensingTemperatureMaximumforIndoorUnit);
153
154 // Outdoor Unit Evaporator Reference Superheating: Optional Double
155
1/1
✓ Branch 1 taken 2 times.
2 double outdoorUnitEvaporatorReferenceSuperheating = modelObject.outdoorUnitEvaporatorReferenceSuperheating();
156
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::OutdoorUnitEvaporatorReferenceSuperheating,
157 outdoorUnitEvaporatorReferenceSuperheating);
158
159 // Outdoor Unit Condenser Reference Subcooling: Optional Double
160
1/1
✓ Branch 1 taken 2 times.
2 double outdoorUnitCondenserReferenceSubcooling = modelObject.outdoorUnitCondenserReferenceSubcooling();
161
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::OutdoorUnitCondenserReferenceSubcooling,
162 outdoorUnitCondenserReferenceSubcooling);
163
164 // Outdoor Unit Evaporator Rated Bypass Factor: Optional Double
165
1/1
✓ Branch 1 taken 2 times.
2 double outdoorUnitEvaporatorRatedBypassFactor = modelObject.outdoorUnitEvaporatorRatedBypassFactor();
166
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::OutdoorUnitEvaporatorRatedBypassFactor,
167 outdoorUnitEvaporatorRatedBypassFactor);
168
169 // Outdoor Unit Condenser Rated Bypass Factor: Optional Double
170
1/1
✓ Branch 1 taken 2 times.
2 double outdoorUnitCondenserRatedBypassFactor = modelObject.outdoorUnitCondenserRatedBypassFactor();
171
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::OutdoorUnitCondenserRatedBypassFactor,
172 outdoorUnitCondenserRatedBypassFactor);
173
174 // Difference between Outdoor Unit Evaporating Temperature and Outdoor Air Temperature in Heat Recovery Mode: Optional Double
175 double differencebetweenOutdoorUnitEvaporatingTemperatureandOutdoorAirTemperatureinHeatRecoveryMode =
176
1/1
✓ Branch 1 taken 2 times.
2 modelObject.differencebetweenOutdoorUnitEvaporatingTemperatureandOutdoorAirTemperatureinHeatRecoveryMode();
177
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::
178 DifferencebetweenOutdoorUnitEvaporatingTemperatureandOutdoorAirTemperatureinHeatRecoveryMode,
179 differencebetweenOutdoorUnitEvaporatingTemperatureandOutdoorAirTemperatureinHeatRecoveryMode);
180
181 // Outdoor Unit Heat Exchanger Capacity Ratio: Optional Double
182
1/1
✓ Branch 1 taken 2 times.
2 double outdoorUnitHeatExchangerCapacityRatio = modelObject.outdoorUnitHeatExchangerCapacityRatio();
183
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::OutdoorUnitHeatExchangerCapacityRatio,
184 outdoorUnitHeatExchangerCapacityRatio);
185
186 // Outdoor Unit Fan Power Per Unit of Rated Evaporative Capacity: Optional Double
187
1/1
✓ Branch 1 taken 2 times.
2 double outdoorUnitFanPowerPerUnitofRatedEvaporativeCapacity = modelObject.outdoorUnitFanPowerPerUnitofRatedEvaporativeCapacity();
188
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::OutdoorUnitFanPowerPerUnitofRatedEvaporativeCapacity,
189 outdoorUnitFanPowerPerUnitofRatedEvaporativeCapacity);
190
191 // Outdoor Unit Fan Flow Rate Per Unit of Rated Evaporative Capacity: Optional Double
192
1/1
✓ Branch 1 taken 2 times.
2 double outdoorUnitFanFlowRatePerUnitofRatedEvaporativeCapacity = modelObject.outdoorUnitFanFlowRatePerUnitofRatedEvaporativeCapacity();
193
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(
194 AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::OutdoorUnitFanFlowRatePerUnitofRatedEvaporativeCapacity,
195 outdoorUnitFanFlowRatePerUnitofRatedEvaporativeCapacity);
196
197 // Outdoor Unit Evaporating Temperature Function of Superheating Curve Name: Required Object
198
1/1
✓ Branch 1 taken 2 times.
2 Curve outdoorUnitEvaporatingTemperatureFunctionofSuperheatingCurve = modelObject.outdoorUnitEvaporatingTemperatureFunctionofSuperheatingCurve();
199
2/3
✓ Branch 1 taken 2 times.
✓ Branch 3 taken 2 times.
✗ Branch 4 not taken.
4 if (boost::optional<IdfObject> owo_ = translateAndMapModelObject(outdoorUnitEvaporatingTemperatureFunctionofSuperheatingCurve)) {
200
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setString(
201 AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::OutdoorUnitEvaporatingTemperatureFunctionofSuperheatingCurveName,
202
2/2
✓ Branch 1 taken 2 times.
✓ Branch 4 taken 2 times.
4 owo_->nameString());
203 2 }
204
205 // Outdoor Unit Condensing Temperature Function of Subcooling Curve Name: Required Object
206
1/1
✓ Branch 1 taken 2 times.
2 Curve outdoorUnitCondensingTemperatureFunctionofSubcoolingCurve = modelObject.outdoorUnitCondensingTemperatureFunctionofSubcoolingCurve();
207
2/3
✓ Branch 1 taken 2 times.
✓ Branch 3 taken 2 times.
✗ Branch 4 not taken.
4 if (boost::optional<IdfObject> owo_ = translateAndMapModelObject(outdoorUnitCondensingTemperatureFunctionofSubcoolingCurve)) {
208
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setString(
209 AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::OutdoorUnitCondensingTemperatureFunctionofSubcoolingCurveName,
210
2/2
✓ Branch 1 taken 2 times.
✓ Branch 4 taken 2 times.
4 owo_->nameString());
211 2 }
212
213 // Diameter of Main Pipe for Suction Gas: Optional Double
214
1/1
✓ Branch 1 taken 2 times.
2 double diameterofMainPipeforSuctionGas = modelObject.diameterofMainPipeforSuctionGas();
215
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::DiameterofMainPipeforSuctionGas,
216 diameterofMainPipeforSuctionGas);
217
218 // Diameter of Main Pipe for Discharge Gas: Optional Double
219
1/1
✓ Branch 1 taken 2 times.
2 double diameterofMainPipeforDischargeGas = modelObject.diameterofMainPipeforDischargeGas();
220
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::DiameterofMainPipeforDischargeGas,
221 diameterofMainPipeforDischargeGas);
222
223 // Length of Main Pipe Connecting Outdoor Unit to the First Branch Joint: Optional Double
224
1/1
✓ Branch 1 taken 2 times.
2 double lengthofMainPipeConnectingOutdoorUnittotheFirstBranchJoint = modelObject.lengthofMainPipeConnectingOutdoorUnittotheFirstBranchJoint();
225
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(
226 AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::LengthofMainPipeConnectingOutdoorUnittotheFirstBranchJoint,
227 lengthofMainPipeConnectingOutdoorUnittotheFirstBranchJoint);
228
229 // Equivalent Length of Main Pipe Connecting Outdoor Unit to the First Branch Joint: Optional Double
230 double equivalentLengthofMainPipeConnectingOutdoorUnittotheFirstBranchJoint =
231
1/1
✓ Branch 1 taken 2 times.
2 modelObject.equivalentLengthofMainPipeConnectingOutdoorUnittotheFirstBranchJoint();
232
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(
233 AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::EquivalentLengthofMainPipeConnectingOutdoorUnittotheFirstBranchJoint,
234 equivalentLengthofMainPipeConnectingOutdoorUnittotheFirstBranchJoint);
235
236 // Height Difference Between Outdoor Unit and Indoor Units: Optional Double
237
1/1
✓ Branch 1 taken 2 times.
2 double heightDifferenceBetweenOutdoorUnitandIndoorUnits = modelObject.heightDifferenceBetweenOutdoorUnitandIndoorUnits();
238
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::HeightDifferenceBetweenOutdoorUnitandIndoorUnits,
239 heightDifferenceBetweenOutdoorUnitandIndoorUnits);
240
241 // Main Pipe Insulation Thickness: Optional Double
242
1/1
✓ Branch 1 taken 2 times.
2 double mainPipeInsulationThickness = modelObject.mainPipeInsulationThickness();
243
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::MainPipeInsulationThickness,
244 mainPipeInsulationThickness);
245
246 // Main Pipe Insulation Thermal Conductivity: Optional Double
247
1/1
✓ Branch 1 taken 2 times.
2 double mainPipeInsulationThermalConductivity = modelObject.mainPipeInsulationThermalConductivity();
248
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::MainPipeInsulationThermalConductivity,
249 mainPipeInsulationThermalConductivity);
250
251 // Crankcase Heater Power per Compressor: Optional Double
252
1/1
✓ Branch 1 taken 2 times.
2 double crankcaseHeaterPowerperCompressor = modelObject.crankcaseHeaterPowerperCompressor();
253
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::CrankcaseHeaterPowerperCompressor,
254 crankcaseHeaterPowerperCompressor);
255
256 // Number of Compressors: Optional Integer
257
1/1
✓ Branch 1 taken 2 times.
2 int numberofCompressors = modelObject.numberofCompressors();
258
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setInt(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::NumberofCompressors, numberofCompressors);
259
260 // Ratio of Compressor Size to Total Compressor Capacity: Optional Double
261
1/1
✓ Branch 1 taken 2 times.
2 double ratioofCompressorSizetoTotalCompressorCapacity = modelObject.ratioofCompressorSizetoTotalCompressorCapacity();
262
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::RatioofCompressorSizetoTotalCompressorCapacity,
263 ratioofCompressorSizetoTotalCompressorCapacity);
264
265 // Maximum Outdoor Dry-Bulb Temperature for Crankcase Heater: Optional Double
266
1/1
✓ Branch 1 taken 2 times.
2 double maximumOutdoorDryBulbTemperatureforCrankcaseHeater = modelObject.maximumOutdoorDryBulbTemperatureforCrankcaseHeater();
267
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::MaximumOutdoorDryBulbTemperatureforCrankcaseHeater,
268 maximumOutdoorDryBulbTemperatureforCrankcaseHeater);
269
270 // Defrost Strategy: Optional String
271
1/1
✓ Branch 1 taken 2 times.
2 std::string defrostStrategy = modelObject.defrostStrategy();
272
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setString(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::DefrostStrategy, defrostStrategy);
273
274 // Defrost Control: Optional String
275
1/1
✓ Branch 1 taken 2 times.
2 std::string defrostControl = modelObject.defrostControl();
276
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setString(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::DefrostControl, defrostControl);
277
278 // Defrost Energy Input Ratio Modifier Function of Temperature Curve Name: Optional Object
279 2 if (boost::optional<Curve> _defrostEnergyInputRatioModifierFunctionofTemperatureCurve =
280
3/3
✓ Branch 1 taken 2 times.
✓ Branch 3 taken 1 time.
✓ Branch 4 taken 1 time.
4 modelObject.defrostEnergyInputRatioModifierFunctionofTemperatureCurve()) {
281
3/4
✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 6 taken 1 time.
✗ Branch 7 not taken.
2 if (boost::optional<IdfObject> owo_ = translateAndMapModelObject(_defrostEnergyInputRatioModifierFunctionofTemperatureCurve.get())) {
282
1/1
✓ Branch 1 taken 1 time.
1 idfObject.setString(
283 AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::DefrostEnergyInputRatioModifierFunctionofTemperatureCurveName,
284
2/2
✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
2 owo_->nameString());
285 1 }
286 2 }
287
288 // Defrost Time Period Fraction: Optional Double
289
1/1
✓ Branch 1 taken 2 times.
2 double defrostTimePeriodFraction = modelObject.defrostTimePeriodFraction();
290
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::DefrostTimePeriodFraction,
291 defrostTimePeriodFraction);
292
293
2/3
✓ Branch 1 taken 2 times.
✗ Branch 3 not taken.
✓ Branch 4 taken 2 times.
2 if (modelObject.isResistiveDefrostHeaterCapacityAutosized()) {
294 ✗ idfObject.setString(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::ResistiveDefrostHeaterCapacity, "Autosize");
295 } else {
296 // Resistive Defrost Heater Capacity: boost::optional<double>
297
2/3
✓ Branch 1 taken 2 times.
✓ Branch 3 taken 2 times.
✗ Branch 4 not taken.
4 if (boost::optional<double> _resistiveDefrostHeaterCapacity = modelObject.resistiveDefrostHeaterCapacity()) {
298 2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::ResistiveDefrostHeaterCapacity,
299
2/2
✓ Branch 1 taken 2 times.
✓ Branch 4 taken 2 times.
2 _resistiveDefrostHeaterCapacity.get());
300 }
301 }
302
303 // Maximum Outdoor Dry-bulb Temperature for Defrost Operation: Optional Double
304
1/1
✓ Branch 1 taken 2 times.
2 double maximumOutdoorDrybulbTemperatureforDefrostOperation = modelObject.maximumOutdoorDrybulbTemperatureforDefrostOperation();
305
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::MaximumOutdoorDrybulbTemperatureforDefrostOperation,
306 maximumOutdoorDrybulbTemperatureforDefrostOperation);
307
308 // Initial Heat Recovery Cooling Capacity Fraction: Optional Double
309
1/1
✓ Branch 1 taken 2 times.
2 double initialHeatRecoveryCoolingCapacityFraction = modelObject.initialHeatRecoveryCoolingCapacityFraction();
310
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::InitialHeatRecoveryCoolingCapacityFraction,
311 initialHeatRecoveryCoolingCapacityFraction);
312
313 // Heat Recovery Cooling Capacity Time Constant: Optional Double
314
1/1
✓ Branch 1 taken 2 times.
2 double heatRecoveryCoolingCapacityTimeConstant = modelObject.heatRecoveryCoolingCapacityTimeConstant();
315
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::HeatRecoveryCoolingCapacityTimeConstant,
316 heatRecoveryCoolingCapacityTimeConstant);
317
318 // Initial Heat Recovery Cooling Energy Fraction: Optional Double
319
1/1
✓ Branch 1 taken 2 times.
2 double initialHeatRecoveryCoolingEnergyFraction = modelObject.initialHeatRecoveryCoolingEnergyFraction();
320
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::InitialHeatRecoveryCoolingEnergyFraction,
321 initialHeatRecoveryCoolingEnergyFraction);
322
323 // Heat Recovery Cooling Energy Time Constant: Optional Double
324
1/1
✓ Branch 1 taken 2 times.
2 double heatRecoveryCoolingEnergyTimeConstant = modelObject.heatRecoveryCoolingEnergyTimeConstant();
325
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::HeatRecoveryCoolingEnergyTimeConstant,
326 heatRecoveryCoolingEnergyTimeConstant);
327
328 // Initial Heat Recovery Heating Capacity Fraction: Optional Double
329
1/1
✓ Branch 1 taken 2 times.
2 double initialHeatRecoveryHeatingCapacityFraction = modelObject.initialHeatRecoveryHeatingCapacityFraction();
330
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::InitialHeatRecoveryHeatingCapacityFraction,
331 initialHeatRecoveryHeatingCapacityFraction);
332
333 // Heat Recovery Heating Capacity Time Constant: Optional Double
334
1/1
✓ Branch 1 taken 2 times.
2 double heatRecoveryHeatingCapacityTimeConstant = modelObject.heatRecoveryHeatingCapacityTimeConstant();
335
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::HeatRecoveryHeatingCapacityTimeConstant,
336 heatRecoveryHeatingCapacityTimeConstant);
337
338 // Initial Heat Recovery Heating Energy Fraction: Optional Double
339
1/1
✓ Branch 1 taken 2 times.
2 double initialHeatRecoveryHeatingEnergyFraction = modelObject.initialHeatRecoveryHeatingEnergyFraction();
340
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::InitialHeatRecoveryHeatingEnergyFraction,
341 initialHeatRecoveryHeatingEnergyFraction);
342
343 // Heat Recovery Heating Energy Time Constant: Optional Double
344
1/1
✓ Branch 1 taken 2 times.
2 double heatRecoveryHeatingEnergyTimeConstant = modelObject.heatRecoveryHeatingEnergyTimeConstant();
345
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::HeatRecoveryHeatingEnergyTimeConstant,
346 heatRecoveryHeatingEnergyTimeConstant);
347
348 // Compressor Maximum Delta Pressure: Optional Double
349
1/1
✓ Branch 1 taken 2 times.
2 double compressorMaximumDeltaPressure = modelObject.compressorMaximumDeltaPressure();
350
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::CompressormaximumdeltaPressure,
351 compressorMaximumDeltaPressure);
352
353 // Compressor Inverter Efficiency: Optional Double
354
1/1
✓ Branch 1 taken 2 times.
2 double compressorInverterEfficiency = modelObject.compressorInverterEfficiency();
355
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::CompressorInverterEfficiency,
356 compressorInverterEfficiency);
357
358 // Compressor Evaporative Capacity Correction Factor: Optional Double
359
1/1
✓ Branch 1 taken 2 times.
2 double compressorEvaporativeCapacityCorrectionFactor = modelObject.compressorEvaporativeCapacityCorrectionFactor();
360
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::CompressorEvaporativeCapacityCorrectionFactor,
361 compressorEvaporativeCapacityCorrectionFactor);
362
363 // Number of Compressor Loading Index Entries: Optional Integer
364
1/1
✓ Branch 1 taken 2 times.
2 std::vector<LoadingIndex> loadingIndexes = modelObject.loadingIndexes();
365
1/2
✓ Branch 1 taken 2 times.
✗ Branch 2 not taken.
2 if (auto num = loadingIndexes.size()) {
366
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setInt(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::NumberofCompressorLoadingIndexEntries, num);
367 }
368
369 // Terminal Unit List
370
371
2/2
✓ Branch 1 taken 2 times.
✓ Branch 4 taken 2 times.
2 IdfObject _zoneTerminalUnitList(IddObjectType::ZoneTerminalUnitList);
372
373
3/3
✓ Branch 1 taken 2 times.
✓ Branch 4 taken 2 times.
✓ Branch 7 taken 2 times.
2 std::string terminalUnitListName = modelObject.name().get() + " Terminal List";
374
375
1/1
✓ Branch 1 taken 2 times.
2 _zoneTerminalUnitList.setString(ZoneTerminalUnitListFields::ZoneTerminalUnitListName, terminalUnitListName);
376
377
1/1
✓ Branch 1 taken 2 times.
2 idfObject.setString(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRFields::ZoneTerminalUnitListName, terminalUnitListName);
378
379
1/1
✓ Branch 1 taken 2 times.
2 m_idfObjects.push_back(_zoneTerminalUnitList);
380
381
2/2
✓ Branch 5 taken 2 times.
✓ Branch 6 taken 2 times.
4 for (auto& terminal : terminals) {
382
1/1
✓ Branch 1 taken 2 times.
2 boost::optional<IdfObject> terminal_ = translateAndMapModelObject(terminal);
383
384
1/3
✗ Branch 1 not taken.
✓ Branch 2 taken 2 times.
✗ Branch 4 not taken.
2 OS_ASSERT(terminal_);
385
386
1/1
✓ Branch 1 taken 2 times.
2 IdfExtensibleGroup eg = _zoneTerminalUnitList.pushExtensibleGroup();
387
388
4/4
✓ Branch 1 taken 2 times.
✓ Branch 4 taken 2 times.
✓ Branch 7 taken 2 times.
✓ Branch 10 taken 2 times.
2 eg.setString(ZoneTerminalUnitListExtensibleFields::ZoneTerminalUnitName, terminal_->name().get());
389 2 }
390
391 // Loading Index Extensible Groups
392
2/2
✓ Branch 5 taken 6 times.
✓ Branch 6 taken 2 times.
8 for (auto& loadingIndex : loadingIndexes) {
393
1/1
✓ Branch 1 taken 6 times.
6 auto eg = idfObject.pushExtensibleGroup();
394
395 // Compressor Speed at Loading Index
396
2/2
✓ Branch 1 taken 6 times.
✓ Branch 4 taken 6 times.
6 eg.setDouble(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRExtensibleFields::CompressorSpeedatLoadingIndex,
397 loadingIndex.compressorSpeed());
398
399 // Loading Index Evaporative Capacity Multiplier Function of Temperature Curve Name
400 {
401
1/1
✓ Branch 1 taken 6 times.
6 auto curve = loadingIndex.evaporativeCapacityMultiplierFunctionofTemperatureCurve();
402
2/3
✓ Branch 1 taken 6 times.
✓ Branch 3 taken 6 times.
✗ Branch 4 not taken.
12 if (auto curve_ = translateAndMapModelObject(curve)) {
403 6 eg.setString(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRExtensibleFields::
404 LoadingIndexEvaporativeCapacityMultiplierFunctionofTemperatureCurveName,
405
4/4
✓ Branch 1 taken 6 times.
✓ Branch 4 taken 6 times.
✓ Branch 7 taken 6 times.
✓ Branch 10 taken 6 times.
6 curve_->name().get());
406 6 }
407 6 }
408
409 // Loading Index Compressor Power Multiplier Function of Temperature Curve Name
410 {
411
1/1
✓ Branch 1 taken 6 times.
6 auto curve = loadingIndex.compressorPowerMultiplierFunctionofTemperatureCurve();
412
2/3
✓ Branch 1 taken 6 times.
✓ Branch 3 taken 6 times.
✗ Branch 4 not taken.
12 if (auto curve_ = translateAndMapModelObject(curve)) {
413 6 eg.setString(AirConditioner_VariableRefrigerantFlow_FluidTemperatureControl_HRExtensibleFields::
414 LoadingIndexCompressorPowerMultiplierFunctionofTemperatureCurveName,
415
4/4
✓ Branch 1 taken 6 times.
✓ Branch 4 taken 6 times.
✓ Branch 7 taken 6 times.
✓ Branch 10 taken 6 times.
6 curve_->name().get());
416 6 }
417 6 }
418 6 }
419
420
1/1
✓ Branch 1 taken 2 times.
2 return idfObject;
421 3 } // End of translate function
422
423 } // end namespace energyplus
424 } // end namespace openstudio
425