Line Branch Exec Source
1 /***********************************************************************************************************************
2 * OpenStudio(R), Copyright (c) Alliance for Energy Innovation, LLC.
3 * See also https://openstudio.net/license
4 ***********************************************************************************************************************/
5
6 #ifndef MODEL_HEATEXCHANGERAIRTOAIRSENSIBLEANDLATENT_HPP
7 #define MODEL_HEATEXCHANGERAIRTOAIRSENSIBLEANDLATENT_HPP
8
9 #include "ModelAPI.hpp"
10 #include "AirToAirComponent.hpp"
11
12 #include "../utilities/core/Deprecated.hpp"
13
14 namespace openstudio {
15
16 namespace model {
17
18 class Schedule;
19 class AirflowNetworkEquivalentDuct;
20 class Curve;
21
22 namespace detail {
23
24 class HeatExchangerAirToAirSensibleAndLatent_Impl;
25
26 } // namespace detail
27
28 /** HeatExchangerAirToAirSensibleAndLatent is a AirToAirComponent that wraps the OpenStudio IDD object 'OS:HeatExchanger:AirToAir:SensibleAndLatent'. */
29 class MODEL_API HeatExchangerAirToAirSensibleAndLatent : public AirToAirComponent
30 {
31
32 public:
33 /** @name Constructors and Destructors */
34 //@{
35
36 /** Constructor. It will **not** instantiate the optional effectivness curve/tables objects and effectiveness will be constant.
37 * You can then call the helper method `bool assignHistoricalEffectivenessCurves()` to assign 4 TableLookups that will match the pre E+ 24.1.0
38 * defaults for Sensible/Latent Effectiveness at 75% Heating/Cooling airflow */
39 explicit HeatExchangerAirToAirSensibleAndLatent(const Model& model);
40
41 130 virtual ~HeatExchangerAirToAirSensibleAndLatent() override = default;
42 // Default the copy and move operators because the virtual dtor is explicit
43 ✗ HeatExchangerAirToAirSensibleAndLatent(const HeatExchangerAirToAirSensibleAndLatent& other) = default;
44 23 HeatExchangerAirToAirSensibleAndLatent(HeatExchangerAirToAirSensibleAndLatent&& other) = default;
45 ✗ HeatExchangerAirToAirSensibleAndLatent& operator=(const HeatExchangerAirToAirSensibleAndLatent&) = default;
46 ✗ HeatExchangerAirToAirSensibleAndLatent& operator=(HeatExchangerAirToAirSensibleAndLatent&&) = default;
47
48 //@}
49
50 static IddObjectType iddObjectType();
51
52 static std::vector<std::string> heatExchangerTypeValues();
53
54 static std::vector<std::string> frostControlTypeValues();
55
56 Schedule availabilitySchedule() const;
57
58 bool setAvailabilitySchedule(Schedule& schedule);
59
60 boost::optional<double> nominalSupplyAirFlowRate() const;
61
62 bool isNominalSupplyAirFlowRateAutosized() const;
63
64 bool setNominalSupplyAirFlowRate(double nominalSupplyAirFlowRate);
65
66 void autosizeNominalSupplyAirFlowRate();
67
68 double sensibleEffectivenessat100HeatingAirFlow() const;
69
70 bool setSensibleEffectivenessat100HeatingAirFlow(double sensibleEffectivenessat100HeatingAirFlow);
71
72 double latentEffectivenessat100HeatingAirFlow() const;
73
74 bool setLatentEffectivenessat100HeatingAirFlow(double latentEffectivenessat100HeatingAirFlow);
75
76 OS_DEPRECATED(3, 8, 0) double sensibleEffectivenessat75HeatingAirFlow() const;
77
78 OS_DEPRECATED(3, 8, 0) bool setSensibleEffectivenessat75HeatingAirFlow(double sensibleEffectivenessat75HeatingAirFlow);
79
80 OS_DEPRECATED(3, 8, 0) double latentEffectivenessat75HeatingAirFlow() const;
81
82 OS_DEPRECATED(3, 8, 0) bool setLatentEffectivenessat75HeatingAirFlow(double latentEffectivenessat75HeatingAirFlow);
83
84 double sensibleEffectivenessat100CoolingAirFlow() const;
85
86 bool setSensibleEffectivenessat100CoolingAirFlow(double sensibleEffectivenessat100CoolingAirFlow);
87
88 double latentEffectivenessat100CoolingAirFlow() const;
89
90 bool setLatentEffectivenessat100CoolingAirFlow(double latentEffectivenessat100CoolingAirFlow);
91
92 OS_DEPRECATED(3, 8, 0) double sensibleEffectivenessat75CoolingAirFlow() const;
93
94 OS_DEPRECATED(3, 8, 0) bool setSensibleEffectivenessat75CoolingAirFlow(double sensibleEffectivenessat75CoolingAirFlow);
95
96 OS_DEPRECATED(3, 8, 0) double latentEffectivenessat75CoolingAirFlow() const;
97
98 OS_DEPRECATED(3, 8, 0) bool setLatentEffectivenessat75CoolingAirFlow(double latentEffectivenessat75CoolingAirFlow);
99
100 double nominalElectricPower() const;
101
102 bool setNominalElectricPower(double nominalElectricPower);
103
104 bool supplyAirOutletTemperatureControl() const;
105
106 bool setSupplyAirOutletTemperatureControl(bool supplyAirOutletTemperatureControl);
107
108 std::string heatExchangerType() const;
109
110 bool setHeatExchangerType(const std::string& heatExchangerType);
111
112 std::string frostControlType() const;
113
114 bool setFrostControlType(const std::string& frostControlType);
115
116 double thresholdTemperature() const;
117
118 bool isThresholdTemperatureDefaulted() const;
119
120 bool setThresholdTemperature(double thresholdTemperature);
121
122 void resetThresholdTemperature();
123
124 boost::optional<double> initialDefrostTimeFraction() const;
125
126 bool setInitialDefrostTimeFraction(double initialDefrostTimeFraction);
127
128 void resetInitialDefrostTimeFraction();
129
130 boost::optional<double> rateofDefrostTimeFractionIncrease() const;
131
132 bool setRateofDefrostTimeFractionIncrease(double rateofDefrostTimeFractionIncrease);
133
134 void resetRateofDefrostTimeFractionIncrease();
135
136 bool economizerLockout() const;
137
138 bool setEconomizerLockout(bool economizerLockout);
139
140 boost::optional<Curve> sensibleEffectivenessofHeatingAirFlowCurve() const;
141 bool setSensibleEffectivenessofHeatingAirFlowCurve(const Curve& sensibleEffectivenessofHeatingAirFlowCurve);
142 void resetSensibleEffectivenessofHeatingAirFlowCurve();
143
144 boost::optional<Curve> latentEffectivenessofHeatingAirFlowCurve() const;
145 bool setLatentEffectivenessofHeatingAirFlowCurve(const Curve& latentEffectivenessofHeatingAirFlowCurve);
146 void resetLatentEffectivenessofHeatingAirFlowCurve();
147
148 boost::optional<Curve> sensibleEffectivenessofCoolingAirFlowCurve() const;
149 bool setSensibleEffectivenessofCoolingAirFlowCurve(const Curve& sensibleEffectivenessofCoolingAirFlowCurve);
150 void resetSensibleEffectivenessofCoolingAirFlowCurve();
151
152 boost::optional<Curve> latentEffectivenessofCoolingAirFlowCurve() const;
153 bool setLatentEffectivenessofCoolingAirFlowCurve(const Curve& latentEffectivenessofCoolingAirFlowCurve);
154 void resetLatentEffectivenessofCoolingAirFlowCurve();
155
156 /** @name Other */
157 //@{
158
159 boost::optional<double> autosizedNominalSupplyAirFlowRate() const;
160
161 AirflowNetworkEquivalentDuct getAirflowNetworkEquivalentDuct(double length, double diameter);
162 boost::optional<AirflowNetworkEquivalentDuct> airflowNetworkEquivalentDuct() const;
163
164 // Helper that creates defaulted Optional Curves (TableLookups) to match the pre E+ 24.1.0 effectiveness defaults
165 bool assignHistoricalEffectivenessCurves();
166
167 //@}
168
169 protected:
170 /// @cond
171 using ImplType = detail::HeatExchangerAirToAirSensibleAndLatent_Impl;
172
173 explicit HeatExchangerAirToAirSensibleAndLatent(std::shared_ptr<detail::HeatExchangerAirToAirSensibleAndLatent_Impl> impl);
174
175 friend class detail::HeatExchangerAirToAirSensibleAndLatent_Impl;
176 friend class Model;
177 friend class IdfObject;
178 friend class openstudio::detail::IdfObject_Impl;
179
180 /// @endcond
181
182 private:
183 − REGISTER_LOGGER("openstudio.model.HeatExchangerAirToAirSensibleAndLatent");
184 };
185
186 /** \relates HeatExchangerAirToAirSensibleAndLatent*/
187 using OptionalHeatExchangerAirToAirSensibleAndLatent = boost::optional<HeatExchangerAirToAirSensibleAndLatent>;
188
189 /** \relates HeatExchangerAirToAirSensibleAndLatent*/
190 using HeatExchangerAirToAirSensibleAndLatentVector = std::vector<HeatExchangerAirToAirSensibleAndLatent>;
191
192 } // namespace model
193 } // namespace openstudio
194
195 #endif // MODEL_HEATEXCHANGERAIRTOAIRSENSIBLEANDLATENT_HPP