GCC Code Coverage Report


Directory: ./
Coverage: low: ≥ 0% medium: ≥ 75.0% high: ≥ 90.0%
Coverage Exec / Excl / Total
Lines: 55.6% 20 / 0 / 36
Functions: 100.0% 1 / 0 / 1
Branches: 37.7% 26 / 0 / 69

src/energyplus/ReverseTranslator/ReverseTranslateCoilCoolingDX.cpp
Line Branch Exec Source
1 /***********************************************************************************************************************
2 * OpenStudio(R), Copyright (c) Alliance for Energy Innovation, LLC.
3 * See also https://openstudio.net/license
4 ***********************************************************************************************************************/
5
6 #include "../ReverseTranslator.hpp"
7
8 #include "../../model/CoilCoolingDX.hpp"
9 #include "../../model/CoilCoolingDX_Impl.hpp"
10
11 #include "../../model/Node.hpp"
12 #include "../../model/Node_Impl.hpp"
13 #include "../../model/Schedule.hpp"
14 #include "../../model/Schedule_Impl.hpp"
15 #include "../../model/ThermalZone.hpp"
16 #include "../../model/ThermalZone_Impl.hpp"
17 #include "../../model/Space.hpp"
18 #include "../../model/Space_Impl.hpp"
19 #include "../../model/CoilCoolingDXCurveFitPerformance.hpp"
20 #include "../../model/CoilCoolingDXCurveFitPerformance_Impl.hpp"
21
22 #include <utilities/idd/Coil_Cooling_DX_FieldEnums.hxx>
23 #include "../../utilities/idd/IddEnums.hpp"
24 #include <utilities/idd/IddEnums.hxx>
25
26 #include "../../utilities/core/Assert.hpp"
27
28 using namespace openstudio::model;
29
30 namespace openstudio {
31
32 namespace energyplus {
33
34 2 OptionalModelObject ReverseTranslator::translateCoilCoolingDX(const WorkspaceObject& workspaceObject) {
35
4/5
✓ Branch 1 taken 2 times.
✓ Branch 4 taken 2 times.
✓ Branch 7 taken 2 times.
✗ Branch 11 not taken.
✓ Branch 12 taken 2 times.
2 if (workspaceObject.iddObject().type() != IddObjectType::Coil_Cooling_DX) {
36 ✗ LOG(Error, "WorkspaceObject is not IddObjectType: CoilCoolingDX");
37 ✗ return boost::none;
38 }
39
40 2 OptionalString s;
41 2 OptionalDouble d;
42 2 OptionalWorkspaceObject target;
43
44 2 boost::optional<CoilCoolingDXCurveFitPerformance> performanceObject;
45
2/3
✓ Branch 1 taken 2 times.
✓ Branch 5 taken 2 times.
✗ Branch 6 not taken.
4 if ((target = workspaceObject.getTarget(openstudio::Coil_Cooling_DXFields::PerformanceObjectName))) {
46
2/2
✓ Branch 1 taken 2 times.
✓ Branch 4 taken 2 times.
2 OptionalModelObject modelObject = translateAndMapWorkspaceObject(*target);
47
1/2
✓ Branch 0 taken 2 times.
✗ Branch 1 not taken.
2 if (modelObject) {
48
3/4
✓ Branch 1 taken 2 times.
✓ Branch 4 taken 2 times.
✓ Branch 7 taken 2 times.
✗ Branch 8 not taken.
4 if (modelObject->optionalCast<CoilCoolingDXCurveFitPerformance>()) {
49
3/3
✓ Branch 1 taken 2 times.
✓ Branch 4 taken 2 times.
✓ Branch 7 taken 2 times.
2 performanceObject = modelObject->cast<CoilCoolingDXCurveFitPerformance>();
50 }
51 }
52 2 }
53
54
2/2
✓ Branch 1 taken 2 times.
✓ Branch 4 taken 2 times.
2 openstudio::model::CoilCoolingDX dx(m_model, *performanceObject);
55
56
1/1
✓ Branch 1 taken 2 times.
2 s = workspaceObject.name();
57
1/2
✓ Branch 0 taken 2 times.
✗ Branch 1 not taken.
2 if (s) {
58
2/2
✓ Branch 1 taken 2 times.
✓ Branch 4 taken 2 times.
2 dx.setName(*s);
59 }
60
61
2/3
✓ Branch 1 taken 2 times.
✗ Branch 5 not taken.
✓ Branch 6 taken 2 times.
4 if ((target = workspaceObject.getTarget(openstudio::Coil_Cooling_DXFields::AvailabilityScheduleName))) {
62 ✗ OptionalModelObject modelObject = translateAndMapWorkspaceObject(*target);
63 ✗ if (modelObject) {
64 ✗ if (auto optSch = modelObject->optionalCast<Schedule>()) {
65 ✗ dx.setAvailabilitySchedule(optSch.get());
66 ✗ }
67 }
68 ✗ }
69
70
2/3
✓ Branch 1 taken 2 times.
✗ Branch 5 not taken.
✓ Branch 6 taken 2 times.
4 if ((target = workspaceObject.getTarget(openstudio::Coil_Cooling_DXFields::CondenserZoneName))) {
71 ✗ if (auto mo_ = translateAndMapWorkspaceObject(*target)) {
72 // Zone is translated, and a Space is returned instead
73 ✗ if (boost::optional<Space> space_ = mo_->optionalCast<Space>()) {
74 ✗ if (auto z_ = space_->thermalZone()) {
75 ✗ dx.setCondenserZone(z_.get());
76 ✗ }
77 } else {
78 ✗ LOG(Warn, workspaceObject.briefDescription() << " has a wrong type for 'Condenser Zone Name'");
79 ✗ }
80 ✗ }
81 }
82
83 // TODO: eventually support the condenser Inlet/Outlet Nodes and the Storage Tanks
84
85
1/1
✓ Branch 1 taken 2 times.
2 return dx;
86 2 } // End of translate function
87
88 } // end namespace energyplus
89 } // end namespace openstudio
90