GCC Code Coverage Report


Directory: ./
Coverage: low: ≥ 0% medium: ≥ 75.0% high: ≥ 90.0%
Coverage Exec / Excl / Total
Lines: 40.0% 2 / 0 / 5
Functions: 40.0% 2 / 0 / 5
Branches: -% 0 / 0 / 0

src/model/AirTerminalSingleDuctConstantVolumeNoReheat.hpp
Line Branch Exec Source
1 /***********************************************************************************************************************
2 * OpenStudio(R), Copyright (c) Alliance for Energy Innovation, LLC.
3 * See also https://openstudio.net/license
4 ***********************************************************************************************************************/
5
6 #ifndef MODEL_AIRTERMINALSINGLEDUCTCONSTANTVOLUMENOREHEAT_HPP
7 #define MODEL_AIRTERMINALSINGLEDUCTCONSTANTVOLUMENOREHEAT_HPP
8
9 #include "ModelObject.hpp"
10 #include "StraightComponent.hpp"
11 #include "Connection.hpp"
12 #include "ModelAPI.hpp"
13
14 namespace openstudio {
15
16 namespace model {
17
18 class Schedule;
19
20 namespace detail {
21
22 class AirTerminalSingleDuctConstantVolumeNoReheat_Impl;
23
24 } // namespace detail
25
26 /** AirTerminalSingleDuctConstantVolumeNoReheat is an interface to the EnergyPlus IDD object
27 * named "AirTerminal:SingleDuct:ConstantVolume:NoReheat"
28 *
29 * The purpose of this class is to simplify the construction and manipulation
30 * AirTerminal:SingleDuct:ConstantVolume:NoReheat objects in energyplus.
31 */
32 class MODEL_API AirTerminalSingleDuctConstantVolumeNoReheat : public StraightComponent
33 {
34
35 public:
36 /** @name Constructors and Destructors */
37 //@{
38
39 /** Constructs a new AirTerminalSingleDuctConstantVolumeNoReheat object and places it inside the
40 * model. The object is fully initialized with all companion objects. */
41 AirTerminalSingleDuctConstantVolumeNoReheat(const Model& model, Schedule& availabilitySchedule);
42
43 555 virtual ~AirTerminalSingleDuctConstantVolumeNoReheat() override = default;
44 // Default the copy and move operators because the virtual dtor is explicit
45 ✗ AirTerminalSingleDuctConstantVolumeNoReheat(const AirTerminalSingleDuctConstantVolumeNoReheat& other) = default;
46 23 AirTerminalSingleDuctConstantVolumeNoReheat(AirTerminalSingleDuctConstantVolumeNoReheat&& other) = default;
47 ✗ AirTerminalSingleDuctConstantVolumeNoReheat& operator=(const AirTerminalSingleDuctConstantVolumeNoReheat&) = default;
48 ✗ AirTerminalSingleDuctConstantVolumeNoReheat& operator=(AirTerminalSingleDuctConstantVolumeNoReheat&&) = default;
49
50 //@}
51
52 static IddObjectType iddObjectType();
53
54 /** Returns the Schedule referred to by the AvailabilityScheduleName field. **/
55 Schedule availabilitySchedule() const;
56
57 /** Sets the Schedule referred to by the AvailabilityScheduleName field. **/
58 bool setAvailabilitySchedule(Schedule& schedule);
59
60 boost::optional<double> maximumAirFlowRate() const;
61
62 bool isMaximumAirFlowRateAutosized() const;
63
64 bool setMaximumAirFlowRate(double maximumAirFlowRate);
65
66 void autosizeMaximumAirFlowRate();
67
68 boost::optional<double> autosizedMaximumAirFlowRate() const;
69
70 //@}
71 protected:
72 friend class Model;
73 friend class openstudio::IdfObject;
74 friend class openstudio::detail::IdfObject_Impl;
75
76 /// @cond
77 using ImplType = detail::AirTerminalSingleDuctConstantVolumeNoReheat_Impl;
78
79 explicit AirTerminalSingleDuctConstantVolumeNoReheat(std::shared_ptr<detail::AirTerminalSingleDuctConstantVolumeNoReheat_Impl> impl);
80
81 private:
82 REGISTER_LOGGER("openstudio.model.AirTerminalSingleDuctConstantVolumeNoReheat");
83 /// @endcond
84 };
85
86 using OptionalAirTerminalSingleDuctConstantVolumeNoReheat = boost::optional<AirTerminalSingleDuctConstantVolumeNoReheat>;
87
88 using AirTerminalSingleDuctConstantVolumeNoReheatVector = std::vector<AirTerminalSingleDuctConstantVolumeNoReheat>;
89
90 // In E+ 9.0.0, ATU SingleDuctUncontrolled was renamed to SingleDuctConstantVolumeNoReheat
91 // To be more consistent with the naming convention of others ATU. We typedef for backwards compatibility
92 using AirTerminalSingleDuctUncontrolled = AirTerminalSingleDuctConstantVolumeNoReheat;
93
94 } // namespace model
95
96 } // namespace openstudio
97
98 #endif // MODEL_AIRTERMINALSINGLEDUCTCONSTANTVOLUMENOREHEAT_HPP
99