src/energyplus/ForwardTranslator/ForwardTranslateAirTerminalSingleDuctConstantVolumeFourPipeBeam.cpp
| Line | Branch | Exec | Source |
|---|---|---|---|
| 1 | /*********************************************************************************************************************** | ||
| 2 | * OpenStudio(R), Copyright (c) Alliance for Energy Innovation, LLC. | ||
| 3 | * See also https://openstudio.net/license | ||
| 4 | ***********************************************************************************************************************/ | ||
| 5 | |||
| 6 | #include "../ForwardTranslator.hpp" | ||
| 7 | |||
| 8 | #include "../../model/Model.hpp" | ||
| 9 | #include "../../model/AirTerminalSingleDuctConstantVolumeFourPipeBeam.hpp" | ||
| 10 | #include "../../model/AirTerminalSingleDuctConstantVolumeFourPipeBeam_Impl.hpp" | ||
| 11 | #include "../../model/CoilCoolingFourPipeBeam.hpp" | ||
| 12 | #include "../../model/CoilCoolingFourPipeBeam_Impl.hpp" | ||
| 13 | #include "../../model/CoilHeatingFourPipeBeam.hpp" | ||
| 14 | #include "../../model/CoilHeatingFourPipeBeam_Impl.hpp" | ||
| 15 | |||
| 16 | #include "../../model/HVACComponent.hpp" | ||
| 17 | #include "../../model/HVACComponent_Impl.hpp" | ||
| 18 | #include "../../model/StraightComponent.hpp" | ||
| 19 | #include "../../model/StraightComponent_Impl.hpp" | ||
| 20 | #include "../../model/AirLoopHVACZoneSplitter.hpp" | ||
| 21 | #include "../../model/AirLoopHVACZoneSplitter_Impl.hpp" | ||
| 22 | #include "../../model/AirLoopHVACZoneMixer.hpp" | ||
| 23 | #include "../../model/AirLoopHVACZoneMixer_Impl.hpp" | ||
| 24 | #include "../../model/Schedule.hpp" | ||
| 25 | #include "../../model/Schedule_Impl.hpp" | ||
| 26 | #include "../../model/Node.hpp" | ||
| 27 | #include "../../model/Node_Impl.hpp" | ||
| 28 | #include "../../model/PlantLoop.hpp" | ||
| 29 | #include "../../model/Curve.hpp" | ||
| 30 | |||
| 31 | #include <utilities/idd/AirTerminal_SingleDuct_ConstantVolume_FourPipeBeam_FieldEnums.hxx> | ||
| 32 | #include <utilities/idd/ZoneHVAC_AirDistributionUnit_FieldEnums.hxx> | ||
| 33 | |||
| 34 | #include "../../utilities/idd/IddEnums.hpp" | ||
| 35 | #include <utilities/idd/IddEnums.hxx> | ||
| 36 | #include <utilities/idd/IddFactory.hxx> | ||
| 37 | |||
| 38 | using namespace openstudio::model; | ||
| 39 | |||
| 40 | namespace openstudio { | ||
| 41 | |||
| 42 | namespace energyplus { | ||
| 43 | |||
| 44 | boost::optional<IdfObject> | ||
| 45 | 3 | ForwardTranslator::translateAirTerminalSingleDuctConstantVolumeFourPipeBeam(AirTerminalSingleDuctConstantVolumeFourPipeBeam& modelObject) { | |
| 46 | |||
| 47 | // Sanity check: this object must be connected to an AirLoopHVAC, and it must have at least one cooling coil or one heating coil that is connected | ||
| 48 | // to a PlantLoop | ||
| 49 |
4/7✓ Branch 1 taken 3 times.
✓ Branch 4 taken 3 times.
✗ Branch 5 not taken.
✓ Branch 7 taken 2 times.
✓ Branch 8 taken 1 time.
✗ Branch 9 not taken.
✗ Branch 10 not taken.
|
9 | if (!(modelObject.airLoopHVAC().is_initialized() |
| 50 |
9/16✓ Branch 1 taken 3 times.
✓ Branch 4 taken 2 times.
✓ Branch 5 taken 1 time.
✓ Branch 7 taken 2 times.
✓ Branch 10 taken 2 times.
✗ Branch 11 not taken.
✓ Branch 12 taken 2 times.
✓ Branch 13 taken 1 time.
✓ Branch 15 taken 3 times.
✗ Branch 16 not taken.
✓ Branch 18 taken 3 times.
✗ Branch 19 not taken.
✗ Branch 20 not taken.
✗ Branch 21 not taken.
✗ Branch 23 not taken.
✗ Branch 24 not taken.
|
6 | && (modelObject.chilledWaterPlantLoop().is_initialized() || modelObject.hotWaterPlantLoop().is_initialized()))) { |
| 51 |
7/7✓ Branch 1 taken 2 times.
✓ Branch 4 taken 2 times.
✓ Branch 7 taken 2 times.
✓ Branch 10 taken 2 times.
✓ Branch 14 taken 2 times.
✓ Branch 17 taken 2 times.
✓ Branch 20 taken 2 times.
|
2 | LOG(Warn, modelObject.briefDescription() << " is not connected to at least one AirLoopHVAC AND one PlantLoop, it will NOT be translated"); |
| 52 | 2 | return boost::none; | |
| 53 | } | ||
| 54 | |||
| 55 | // Name | ||
| 56 |
2/2✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
|
1 | IdfObject idfObject(openstudio::IddObjectType::AirTerminal_SingleDuct_ConstantVolume_FourPipeBeam); |
| 57 |
1/1✓ Branch 1 taken 1 time.
|
1 | m_idfObjects.push_back(idfObject); |
| 58 | |||
| 59 | // A1 , \field Name | ||
| 60 |
3/3✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 7 taken 1 time.
|
1 | std::string baseName = modelObject.name().get(); |
| 61 |
1/1✓ Branch 1 taken 1 time.
|
1 | idfObject.setName(baseName); |
| 62 | |||
| 63 | //register the air distribution unit in the map rather than the chilled beam air terminal itself. | ||
| 64 | //this is necessary because the air distribution unit encapsulating the chilled beam air terminal | ||
| 65 | //goes on both the brachlist and the zone HVAC equipment list | ||
| 66 | //since the branches are translated first, when the chilled beam's coil is encountered in the branchlist, the air distribution unit | ||
| 67 | //that encapsulates the chilled beam is returned and put onto the branch list. | ||
| 68 | //When the chilled beam air terminal is encountered again on the zone HVAC equipment list, | ||
| 69 | //the map must return the air distribution unit to ensure that the air distribution unit is on the translated | ||
| 70 | //equipment list. | ||
| 71 | |||
| 72 |
2/2✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
|
1 | IdfObject _airDistributionUnit(IddObjectType::ZoneHVAC_AirDistributionUnit); |
| 73 |
2/2✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
|
1 | _airDistributionUnit.setName("ADU " + baseName); //ADU: Air Distribution Unit |
| 74 |
1/1✓ Branch 1 taken 1 time.
|
1 | m_idfObjects.push_back(_airDistributionUnit); |
| 75 | |||
| 76 | 1 | boost::optional<std::string> s; | |
| 77 | 1 | boost::optional<double> optD; | |
| 78 | 1 | boost::optional<ModelObject> temp; | |
| 79 | |||
| 80 | // A2 , \field Primary Air Availability Schedule Name | ||
| 81 | { | ||
| 82 |
1/1✓ Branch 1 taken 1 time.
|
1 | Schedule schedule = modelObject.primaryAirAvailabilitySchedule(); |
| 83 |
2/3✓ Branch 1 taken 1 time.
✓ Branch 3 taken 1 time.
✗ Branch 4 not taken.
|
2 | if (boost::optional<IdfObject> _schedule = translateAndMapModelObject(schedule)) { |
| 84 |
4/4✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 7 taken 1 time.
✓ Branch 10 taken 1 time.
|
1 | idfObject.setString(AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::PrimaryAirAvailabilityScheduleName, _schedule->name().get()); |
| 85 | 1 | } | |
| 86 | 1 | } | |
| 87 | |||
| 88 | // A3 , \field Cooling Availability Schedule Name | ||
| 89 | { | ||
| 90 |
1/1✓ Branch 1 taken 1 time.
|
1 | Schedule schedule = modelObject.coolingAvailabilitySchedule(); |
| 91 |
2/3✓ Branch 1 taken 1 time.
✓ Branch 3 taken 1 time.
✗ Branch 4 not taken.
|
2 | if (boost::optional<IdfObject> _schedule = translateAndMapModelObject(schedule)) { |
| 92 |
4/4✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 7 taken 1 time.
✓ Branch 10 taken 1 time.
|
1 | idfObject.setString(AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::CoolingAvailabilityScheduleName, _schedule->name().get()); |
| 93 | 1 | } | |
| 94 | 1 | } | |
| 95 | |||
| 96 | // A4 , \field Heating Availability Schedule Name | ||
| 97 | { | ||
| 98 |
1/1✓ Branch 1 taken 1 time.
|
1 | Schedule schedule = modelObject.heatingAvailabilitySchedule(); |
| 99 |
2/3✓ Branch 1 taken 1 time.
✓ Branch 3 taken 1 time.
✗ Branch 4 not taken.
|
2 | if (boost::optional<IdfObject> _schedule = translateAndMapModelObject(schedule)) { |
| 100 |
4/4✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 7 taken 1 time.
✓ Branch 10 taken 1 time.
|
1 | idfObject.setString(AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::HeatingAvailabilityScheduleName, _schedule->name().get()); |
| 101 | 1 | } | |
| 102 | 1 | } | |
| 103 | |||
| 104 | // A5 , \field Primary Air Inlet Node Name | ||
| 105 |
1/1✓ Branch 1 taken 1 time.
|
1 | temp = modelObject.inletModelObject(); |
| 106 |
1/2✓ Branch 0 taken 1 time.
✗ Branch 1 not taken.
|
1 | if (temp) { |
| 107 |
3/4✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 8 taken 1 time.
✗ Branch 9 not taken.
|
2 | if ((s = temp->name())) { |
| 108 |
2/2✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
|
1 | idfObject.setString(AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::PrimaryAirInletNodeName, s.get()); |
| 109 | } | ||
| 110 | } | ||
| 111 | |||
| 112 | // A6 , \field Primary Air Outlet Node Name | ||
| 113 |
1/1✓ Branch 1 taken 1 time.
|
1 | temp = modelObject.outletModelObject(); |
| 114 |
1/2✓ Branch 0 taken 1 time.
✗ Branch 1 not taken.
|
1 | if (temp) { |
| 115 |
3/4✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 8 taken 1 time.
✗ Branch 9 not taken.
|
2 | if ((s = temp->name())) { |
| 116 |
2/2✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
|
1 | idfObject.setString(AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::PrimaryAirOutletNodeName, s.get()); |
| 117 | } | ||
| 118 | } | ||
| 119 | |||
| 120 | /* Double autosizable fields */ | ||
| 121 | |||
| 122 | // N1 , \field Design Primary Air Volume Flow Rate | ||
| 123 |
2/3✓ Branch 1 taken 1 time.
✓ Branch 3 taken 1 time.
✗ Branch 4 not taken.
|
1 | if (modelObject.isDesignPrimaryAirVolumeFlowRateAutosized()) { |
| 124 |
2/2✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
|
2 | idfObject.setString(AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::DesignPrimaryAirVolumeFlowRate, "Autosize"); |
| 125 | ✗ | } else if ((optD = modelObject.designPrimaryAirVolumeFlowRate())) { | |
| 126 | ✗ | idfObject.setDouble(AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::DesignPrimaryAirVolumeFlowRate, optD.get()); | |
| 127 | } | ||
| 128 | |||
| 129 | // N2 , \field Design Chilled Water Volume Flow Rate | ||
| 130 |
2/3✓ Branch 1 taken 1 time.
✓ Branch 3 taken 1 time.
✗ Branch 4 not taken.
|
1 | if (modelObject.isDesignChilledWaterVolumeFlowRateAutosized()) { |
| 131 |
2/2✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
|
2 | idfObject.setString(AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::DesignChilledWaterVolumeFlowRate, "Autosize"); |
| 132 | ✗ | } else if ((optD = modelObject.designChilledWaterVolumeFlowRate())) { | |
| 133 | ✗ | idfObject.setDouble(AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::DesignChilledWaterVolumeFlowRate, optD.get()); | |
| 134 | } | ||
| 135 | |||
| 136 | // N3 , \field Design Hot Water Volume Flow Rate | ||
| 137 |
2/3✓ Branch 1 taken 1 time.
✗ Branch 3 not taken.
✓ Branch 4 taken 1 time.
|
1 | if (modelObject.isDesignHotWaterVolumeFlowRateAutosized()) { |
| 138 | ✗ | idfObject.setString(AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::DesignHotWaterVolumeFlowRate, "Autosize"); | |
| 139 |
2/3✓ Branch 1 taken 1 time.
✓ Branch 3 taken 1 time.
✗ Branch 4 not taken.
|
2 | } else if ((optD = modelObject.designHotWaterVolumeFlowRate())) { |
| 140 |
2/2✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
|
1 | idfObject.setDouble(AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::DesignHotWaterVolumeFlowRate, optD.get()); |
| 141 | } | ||
| 142 | |||
| 143 | // N4 , \field Zone Total Beam Length | ||
| 144 |
2/3✓ Branch 1 taken 1 time.
✓ Branch 3 taken 1 time.
✗ Branch 4 not taken.
|
1 | if (modelObject.isZoneTotalBeamLengthAutosized()) { |
| 145 |
2/2✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
|
2 | idfObject.setString(AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::ZoneTotalBeamLength, "Autosize"); |
| 146 | ✗ | } else if ((optD = modelObject.zoneTotalBeamLength())) { | |
| 147 | ✗ | idfObject.setDouble(AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::ZoneTotalBeamLength, optD.get()); | |
| 148 | } | ||
| 149 | |||
| 150 | /* Double, with defaults */ | ||
| 151 | |||
| 152 | // N5 , \field Rated Primary Air Flow Rate per Beam Length | ||
| 153 | { | ||
| 154 |
1/1✓ Branch 1 taken 1 time.
|
1 | double value = modelObject.ratedPrimaryAirFlowRateperBeamLength(); |
| 155 |
1/1✓ Branch 1 taken 1 time.
|
1 | idfObject.setDouble(AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::RatedPrimaryAirFlowRateperBeamLength, value); |
| 156 | } | ||
| 157 | |||
| 158 | // Cooling Side: everything is carried on the subclass CoilCoolingFourPipeBeam | ||
| 159 | |||
| 160 |
2/3✓ Branch 1 taken 1 time.
✓ Branch 3 taken 1 time.
✗ Branch 4 not taken.
|
2 | if (boost::optional<HVACComponent> _comp = modelObject.coolingCoil()) { |
| 161 | |||
| 162 |
2/2✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
|
1 | boost::optional<CoilCoolingFourPipeBeam> _cc = _comp->optionalCast<CoilCoolingFourPipeBeam>(); |
| 163 | |||
| 164 |
1/2✗ Branch 1 not taken.
✓ Branch 2 taken 1 time.
|
1 | if (!_cc.is_initialized()) { |
| 165 | ✗ | LOG(Error, "Cooling coil is not a CoilCoolingFourPipeBeam for " << modelObject.briefDescription() << ". Coil will not be translated"); | |
| 166 | } else { | ||
| 167 |
2/2✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
|
1 | CoilCoolingFourPipeBeam cc = _cc.get(); |
| 168 | |||
| 169 | // It it isn't connected to a plantLoop, it's useless... | ||
| 170 | // If it is connected to a plantloop, all three curves are required fields | ||
| 171 | |||
| 172 | /* Curves: all three are required if the FourPipeBeam is connected to a chilled water plant loop, which is the case if we have reached this | ||
| 173 | * point, so I will log and not translate is they aren't defined | ||
| 174 | * Note that since I assign curves in the Ctor and there isn't a reset function for the curves, we shouldn't really have a reason to have a | ||
| 175 | * problem unless something went wrong at some point (or someone used setString("") on the field or something) */ | ||
| 176 | |||
| 177 | // A11, \field Beam Cooling Capacity Temperature Difference Modification Factor Curve Name | ||
| 178 |
2/2✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
|
1 | boost::optional<Curve> capModFuncOfTempDiff = cc.beamCoolingCapacityTemperatureDifferenceModificationFactorCurve(); |
| 179 | |||
| 180 | // A12, \field Beam Cooling Capacity Air Flow Modification Factor Curve Name | ||
| 181 |
2/2✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
|
1 | boost::optional<Curve> capModFuncOfSAFlow = cc.beamCoolingCapacityAirFlowModificationFactorCurve(); |
| 182 | |||
| 183 | // A13, \field Beam Cooling Capacity Chilled Water Flow Modification Factor Curve Name | ||
| 184 |
2/2✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
|
1 | boost::optional<Curve> capModFuncOfWaterFlow = cc.beamCoolingCapacityChilledWaterFlowModificationFactorCurve(); |
| 185 | // Check that it is connected to a plantLoop | ||
| 186 |
3/4✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✗ Branch 8 not taken.
✓ Branch 9 taken 1 time.
|
1 | if (!_cc->plantLoop().is_initialized()) { |
| 187 | ✗ | LOG(Warn, "The Cooling side of " << modelObject.briefDescription() << " isn't connected to a plantLoop, it will not be translated"); | |
| 188 | |||
| 189 | // It MUST have the three curves defined in this case | ||
| 190 |
4/8✓ Branch 1 taken 1 time.
✗ Branch 2 not taken.
✓ Branch 4 taken 1 time.
✗ Branch 5 not taken.
✗ Branch 7 not taken.
✓ Branch 8 taken 1 time.
✗ Branch 9 not taken.
✓ Branch 10 taken 1 time.
|
1 | } else if (!capModFuncOfTempDiff.is_initialized() || !capModFuncOfSAFlow.is_initialized() || !capModFuncOfWaterFlow.is_initialized()) { |
| 191 | ✗ | LOG(Warn, "If you connect the cooling side of " << modelObject.briefDescription() | |
| 192 | << " to a plantLoop, you MUST supply all three curves in the subobject " | ||
| 193 | << cc.briefDescription()); | ||
| 194 | |||
| 195 | } else { | ||
| 196 | // A7 , \field Chilled Water Inlet Node Name | ||
| 197 |
1/1✓ Branch 1 taken 1 time.
|
1 | temp = cc.inletModelObject(); |
| 198 |
1/2✓ Branch 0 taken 1 time.
✗ Branch 1 not taken.
|
1 | if (temp) { |
| 199 |
3/4✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 8 taken 1 time.
✗ Branch 9 not taken.
|
2 | if ((s = temp->name())) { |
| 200 |
2/2✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
|
1 | idfObject.setString(AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::ChilledWaterInletNodeName, s.get()); |
| 201 | } | ||
| 202 | } | ||
| 203 | // A8 , \field Chilled Water Outlet Node Name | ||
| 204 |
1/1✓ Branch 1 taken 1 time.
|
1 | temp = cc.outletModelObject(); |
| 205 |
1/2✓ Branch 0 taken 1 time.
✗ Branch 1 not taken.
|
1 | if (temp) { |
| 206 |
3/4✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 8 taken 1 time.
✗ Branch 9 not taken.
|
2 | if ((s = temp->name())) { |
| 207 |
2/2✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
|
1 | idfObject.setString(AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::ChilledWaterOutletNodeName, s.get()); |
| 208 | } | ||
| 209 | } | ||
| 210 | |||
| 211 | /* Double with defaults (not optionals) */ | ||
| 212 | |||
| 213 | // N6 , \field Beam Rated Cooling Capacity per Beam Length | ||
| 214 | { | ||
| 215 |
1/1✓ Branch 1 taken 1 time.
|
1 | double value = cc.beamRatedCoolingCapacityperBeamLength(); |
| 216 |
1/1✓ Branch 1 taken 1 time.
|
1 | idfObject.setDouble(AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::BeamRatedCoolingCapacityperBeamLength, value); |
| 217 | } | ||
| 218 | |||
| 219 | // N7 , \field Beam Rated Cooling Room Air Chilled Water Temperature Difference | ||
| 220 | { | ||
| 221 |
1/1✓ Branch 1 taken 1 time.
|
1 | double value = cc.beamRatedCoolingRoomAirChilledWaterTemperatureDifference(); |
| 222 |
1/1✓ Branch 1 taken 1 time.
|
1 | idfObject.setDouble(AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::BeamRatedCoolingRoomAirChilledWaterTemperatureDifference, |
| 223 | value); | ||
| 224 | } | ||
| 225 | |||
| 226 | // N8 , \field Beam Rated Chilled Water Volume Flow Rate per Beam Length | ||
| 227 | { | ||
| 228 |
1/1✓ Branch 1 taken 1 time.
|
1 | double value = cc.beamRatedChilledWaterVolumeFlowRateperBeamLength(); |
| 229 |
1/1✓ Branch 1 taken 1 time.
|
1 | idfObject.setDouble(AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::BeamRatedChilledWaterVolumeFlowRateperBeamLength, value); |
| 230 | } | ||
| 231 | |||
| 232 | /* Curves: At this point, I have alreaady checked above that all three curves are defined */ | ||
| 233 | |||
| 234 | // A11, \field Beam Cooling Capacity Temperature Difference Modification Factor Curve Name | ||
| 235 |
3/4✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 6 taken 1 time.
✗ Branch 7 not taken.
|
2 | if (auto _curve = translateAndMapModelObject(capModFuncOfTempDiff.get())) { |
| 236 | 1 | idfObject.setString( | |
| 237 | AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::BeamCoolingCapacityTemperatureDifferenceModificationFactorCurveName, | ||
| 238 |
4/4✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 7 taken 1 time.
✓ Branch 10 taken 1 time.
|
1 | _curve->name().get()); |
| 239 | 1 | } | |
| 240 | |||
| 241 | // A12, \field Beam Cooling Capacity Air Flow Modification Factor Curve Name | ||
| 242 |
3/4✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 6 taken 1 time.
✗ Branch 7 not taken.
|
2 | if (auto _curve = translateAndMapModelObject(capModFuncOfSAFlow.get())) { |
| 243 | 1 | idfObject.setString(AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::BeamCoolingCapacityAirFlowModificationFactorCurveName, | |
| 244 |
4/4✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 7 taken 1 time.
✓ Branch 10 taken 1 time.
|
1 | _curve->name().get()); |
| 245 | 1 | } | |
| 246 | |||
| 247 | // A13, \field Beam Cooling Capacity Chilled Water Flow Modification Factor Curve Name | ||
| 248 |
3/4✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 6 taken 1 time.
✗ Branch 7 not taken.
|
2 | if (auto _curve = translateAndMapModelObject(capModFuncOfWaterFlow.get())) { |
| 249 | 1 | idfObject.setString( | |
| 250 | AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::BeamCoolingCapacityChilledWaterFlowModificationFactorCurveName, | ||
| 251 |
4/4✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 7 taken 1 time.
✓ Branch 10 taken 1 time.
|
1 | _curve->name().get()); |
| 252 | 1 | } | |
| 253 | } | ||
| 254 | 1 | } | |
| 255 | 2 | } | |
| 256 | |||
| 257 | /** | ||
| 258 | * HEATING SIDE: everything is carried on the subclass CoilHeatingFourPipeBeam | ||
| 259 | */ | ||
| 260 | |||
| 261 |
2/3✓ Branch 1 taken 1 time.
✓ Branch 3 taken 1 time.
✗ Branch 4 not taken.
|
2 | if (boost::optional<HVACComponent> _comp = modelObject.heatingCoil()) { |
| 262 | |||
| 263 |
2/2✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
|
1 | boost::optional<CoilHeatingFourPipeBeam> _hc = _comp->optionalCast<CoilHeatingFourPipeBeam>(); |
| 264 | |||
| 265 |
1/2✗ Branch 1 not taken.
✓ Branch 2 taken 1 time.
|
1 | if (!_hc.is_initialized()) { |
| 266 | ✗ | LOG(Error, "Heating coil is not a CoilHeatingFourPipeBeam for " << modelObject.briefDescription() << ". Coil will not be translated"); | |
| 267 | } else { | ||
| 268 | |||
| 269 |
2/2✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
|
1 | CoilHeatingFourPipeBeam hc = _hc.get(); |
| 270 | |||
| 271 | // It it isn't connected to a plantLoop, it's useless... | ||
| 272 | // If it is connected to a plantloop, all three curves are required fields | ||
| 273 | |||
| 274 | /* Curves: all three are required if the FourPipeBeam is connected to a hot water plant loop, which is the case if we have reached this | ||
| 275 | * point, so I will log and not translate is they aren't defined */ | ||
| 276 | |||
| 277 | // A11, \field Beam Heating Capacity Temperature Difference Modification Factor Curve Name | ||
| 278 |
2/2✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
|
1 | boost::optional<Curve> capModFuncOfTempDiff = hc.beamHeatingCapacityTemperatureDifferenceModificationFactorCurve(); |
| 279 | |||
| 280 | // A12, \field Beam Heating Capacity Air Flow Modification Factor Curve Name | ||
| 281 |
2/2✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
|
1 | boost::optional<Curve> capModFuncOfSAFlow = hc.beamHeatingCapacityAirFlowModificationFactorCurve(); |
| 282 | |||
| 283 | // A13, \field Beam Heating Capacity Hot Water Flow Modification Factor Curve Name | ||
| 284 |
2/2✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
|
1 | boost::optional<Curve> capModFuncOfWaterFlow = hc.beamHeatingCapacityHotWaterFlowModificationFactorCurve(); |
| 285 | // Check that it is connected to a plantLoop | ||
| 286 |
3/4✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✗ Branch 8 not taken.
✓ Branch 9 taken 1 time.
|
1 | if (!_hc->plantLoop().is_initialized()) { |
| 287 | ✗ | LOG(Warn, "The Heating side of " << modelObject.briefDescription() << " isn't connected to a plantLoop, it will not be translated"); | |
| 288 | |||
| 289 | // It MUST have the three curves defined in this case | ||
| 290 |
4/8✓ Branch 1 taken 1 time.
✗ Branch 2 not taken.
✓ Branch 4 taken 1 time.
✗ Branch 5 not taken.
✗ Branch 7 not taken.
✓ Branch 8 taken 1 time.
✗ Branch 9 not taken.
✓ Branch 10 taken 1 time.
|
1 | } else if (!capModFuncOfTempDiff.is_initialized() || !capModFuncOfSAFlow.is_initialized() || !capModFuncOfWaterFlow.is_initialized()) { |
| 291 | ✗ | LOG(Warn, "If you connect the heating side of " << modelObject.briefDescription() | |
| 292 | << " to a plantLoop, you MUST supply all three curves in the subobject " | ||
| 293 | << hc.briefDescription()); | ||
| 294 | |||
| 295 | } else { | ||
| 296 | // A9 , \field Hot Water Inlet Node Name | ||
| 297 |
1/1✓ Branch 1 taken 1 time.
|
1 | temp = hc.inletModelObject(); |
| 298 |
1/2✓ Branch 0 taken 1 time.
✗ Branch 1 not taken.
|
1 | if (temp) { |
| 299 |
3/4✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 8 taken 1 time.
✗ Branch 9 not taken.
|
2 | if ((s = temp->name())) { |
| 300 |
2/2✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
|
1 | idfObject.setString(AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::HotWaterInletNodeName, s.get()); |
| 301 | } | ||
| 302 | } | ||
| 303 | // A10 , \field Hot Water Outlet Node Name | ||
| 304 |
1/1✓ Branch 1 taken 1 time.
|
1 | temp = hc.outletModelObject(); |
| 305 |
1/2✓ Branch 0 taken 1 time.
✗ Branch 1 not taken.
|
1 | if (temp) { |
| 306 |
3/4✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 8 taken 1 time.
✗ Branch 9 not taken.
|
2 | if ((s = temp->name())) { |
| 307 |
2/2✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
|
1 | idfObject.setString(AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::HotWaterOutletNodeName, s.get()); |
| 308 | } | ||
| 309 | } | ||
| 310 | |||
| 311 | /* Double with defaults (not optionals) */ | ||
| 312 | |||
| 313 | // N9 , \field Beam Rated Heating Capacity per Beam Length | ||
| 314 | { | ||
| 315 |
1/1✓ Branch 1 taken 1 time.
|
1 | double value = hc.beamRatedHeatingCapacityperBeamLength(); |
| 316 |
1/1✓ Branch 1 taken 1 time.
|
1 | idfObject.setDouble(AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::BeamRatedHeatingCapacityperBeamLength, value); |
| 317 | } | ||
| 318 | |||
| 319 | // N10, \field Beam Rated Heating Room Air Hot Water Temperature Difference | ||
| 320 | { | ||
| 321 |
1/1✓ Branch 1 taken 1 time.
|
1 | double value = hc.beamRatedHeatingRoomAirHotWaterTemperatureDifference(); |
| 322 |
1/1✓ Branch 1 taken 1 time.
|
1 | idfObject.setDouble(AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::BeamRatedHeatingRoomAirHotWaterTemperatureDifference, |
| 323 | value); | ||
| 324 | } | ||
| 325 | |||
| 326 | // N11, \field Beam Rated Hot Water Volume Flow Rate per Beam Length | ||
| 327 | { | ||
| 328 |
1/1✓ Branch 1 taken 1 time.
|
1 | double value = hc.beamRatedHotWaterVolumeFlowRateperBeamLength(); |
| 329 |
1/1✓ Branch 1 taken 1 time.
|
1 | idfObject.setDouble(AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::BeamRatedHotWaterVolumeFlowRateperBeamLength, value); |
| 330 | } | ||
| 331 | |||
| 332 | /* Curves: At this point, I have already checked above that all three curves are defined */ | ||
| 333 | |||
| 334 | // A14, \field Beam Heating Capacity Temperature Difference Modification Factor Curve Name | ||
| 335 |
3/4✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 6 taken 1 time.
✗ Branch 7 not taken.
|
2 | if (auto _curve = translateAndMapModelObject(capModFuncOfTempDiff.get())) { |
| 336 | 1 | idfObject.setString( | |
| 337 | AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::BeamHeatingCapacityTemperatureDifferenceModificationFactorCurveName, | ||
| 338 |
4/4✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 7 taken 1 time.
✓ Branch 10 taken 1 time.
|
1 | _curve->name().get()); |
| 339 | 1 | } | |
| 340 | |||
| 341 | // A15, \field Beam Heating Capacity Air Flow Modification Factor Curve Name | ||
| 342 |
3/4✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 6 taken 1 time.
✗ Branch 7 not taken.
|
2 | if (auto _curve = translateAndMapModelObject(capModFuncOfSAFlow.get())) { |
| 343 | 1 | idfObject.setString(AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::BeamHeatingCapacityAirFlowModificationFactorCurveName, | |
| 344 |
4/4✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 7 taken 1 time.
✓ Branch 10 taken 1 time.
|
1 | _curve->name().get()); |
| 345 | 1 | } | |
| 346 | |||
| 347 | // A16, \field Beam Heating Capacity Hot Water Flow Modification Factor Curve Name | ||
| 348 |
3/4✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 6 taken 1 time.
✗ Branch 7 not taken.
|
2 | if (auto _curve = translateAndMapModelObject(capModFuncOfWaterFlow.get())) { |
| 349 | 1 | idfObject.setString(AirTerminal_SingleDuct_ConstantVolume_FourPipeBeamFields::BeamHeatingCapacityHotWaterFlowModificationFactorCurveName, | |
| 350 |
4/4✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 7 taken 1 time.
✓ Branch 10 taken 1 time.
|
1 | _curve->name().get()); |
| 351 | 1 | } | |
| 352 | } | ||
| 353 | 1 | } | |
| 354 | 2 | } | |
| 355 | |||
| 356 | // Populate fields for AirDistributionUnit | ||
| 357 |
2/3✓ Branch 1 taken 1 time.
✓ Branch 3 taken 1 time.
✗ Branch 4 not taken.
|
2 | if (boost::optional<ModelObject> outletNode = modelObject.outletModelObject()) { |
| 358 |
4/4✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 7 taken 1 time.
✓ Branch 10 taken 1 time.
|
1 | _airDistributionUnit.setString(ZoneHVAC_AirDistributionUnitFields::AirDistributionUnitOutletNodeName, outletNode->name().get()); |
| 359 | 1 | } | |
| 360 |
3/3✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 7 taken 1 time.
|
1 | _airDistributionUnit.setString(ZoneHVAC_AirDistributionUnitFields::AirTerminalObjectType, idfObject.iddObject().name()); |
| 361 |
3/3✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 7 taken 1 time.
|
1 | _airDistributionUnit.setString(ZoneHVAC_AirDistributionUnitFields::AirTerminalName, idfObject.name().get()); |
| 362 | |||
| 363 |
1/1✓ Branch 1 taken 1 time.
|
1 | return _airDistributionUnit; |
| 364 | 1 | } | |
| 365 | |||
| 366 | } // namespace energyplus | ||
| 367 | |||
| 368 | } // namespace openstudio | ||
| 369 |