GCC Code Coverage Report


Directory: ./
Coverage: low: ≥ 0% medium: ≥ 75.0% high: ≥ 90.0%
Coverage Exec / Excl / Total
Lines: 74.2% 23 / 0 / 31
Functions: 100.0% 1 / 0 / 1
Branches: 46.1% 35 / 0 / 76

src/energyplus/ReverseTranslator/ReverseTranslateAirTerminalSingleDuctConstantVolumeNoReheat.cpp
Line Branch Exec Source
1 /***********************************************************************************************************************
2 * OpenStudio(R), Copyright (c) Alliance for Energy Innovation, LLC.
3 * See also https://openstudio.net/license
4 ***********************************************************************************************************************/
5
6 #include "../ReverseTranslator.hpp"
7 #include "../../model/AirTerminalSingleDuctConstantVolumeNoReheat.hpp"
8 #include "../../model/AirTerminalSingleDuctConstantVolumeNoReheat_Impl.hpp"
9 #include "../../model/Schedule.hpp"
10 #include "../../model/Schedule_Impl.hpp"
11 #include <utilities/idd/AirTerminal_SingleDuct_ConstantVolume_NoReheat_FieldEnums.hxx>
12 #include "../../utilities/idd/IddEnums.hpp"
13 #include <utilities/idd/IddEnums.hxx>
14
15 using namespace openstudio::model;
16
17 namespace openstudio {
18
19 namespace energyplus {
20
21 20 OptionalModelObject ReverseTranslator::translateAirTerminalSingleDuctConstantVolumeNoReheat(const WorkspaceObject& workspaceObject) {
22
4/5
✓ Branch 1 taken 20 times.
✓ Branch 4 taken 20 times.
✓ Branch 7 taken 20 times.
✗ Branch 11 not taken.
✓ Branch 12 taken 20 times.
20 if ((workspaceObject.iddObject().type() != IddObjectType::AirTerminal_SingleDuct_ConstantVolume_NoReheat)) {
23 ✗ LOG(Error, "WorkspaceObject is not IddObjectType: AirTerminal_SingleDuct_ConstantVolume_NoReheat");
24 ✗ return boost::none;
25 }
26
27
1/1
✓ Branch 1 taken 20 times.
20 boost::optional<WorkspaceObject> wo = workspaceObject.getTarget(AirTerminal_SingleDuct_ConstantVolume_NoReheatFields::AvailabilityScheduleName);
28 20 boost::optional<Schedule> schedule;
29 20 boost::optional<AirTerminalSingleDuctConstantVolumeNoReheat> airTerminal;
30 20 boost::optional<double> value;
31
32
1/2
✓ Branch 0 taken 20 times.
✗ Branch 1 not taken.
20 if (wo) {
33
2/2
✓ Branch 1 taken 20 times.
✓ Branch 4 taken 20 times.
20 boost::optional<ModelObject> mo = translateAndMapWorkspaceObject(wo.get());
34
1/2
✓ Branch 0 taken 20 times.
✗ Branch 1 not taken.
20 if (mo) {
35
3/4
✓ Branch 1 taken 20 times.
✓ Branch 4 taken 20 times.
✗ Branch 9 not taken.
✓ Branch 10 taken 20 times.
20 if (!(schedule = mo->optionalCast<Schedule>())) {
36 ✗ LOG(Error, workspaceObject.briefDescription() << " does not have an associated availability schedule");
37
38 ✗ return boost::none;
39 }
40 }
41 20 }
42
43
1/2
✓ Branch 0 taken 20 times.
✗ Branch 1 not taken.
20 if (schedule) {
44
3/3
✓ Branch 1 taken 20 times.
✓ Branch 4 taken 20 times.
✓ Branch 7 taken 20 times.
20 airTerminal = AirTerminalSingleDuctConstantVolumeNoReheat(m_model, schedule.get());
45 }
46
47
1/2
✓ Branch 0 taken 20 times.
✗ Branch 1 not taken.
20 if (airTerminal) {
48
1/1
✓ Branch 1 taken 20 times.
20 boost::optional<std::string> s = workspaceObject.getString(AirTerminal_SingleDuct_ConstantVolume_NoReheatFields::Name);
49
1/2
✓ Branch 0 taken 20 times.
✗ Branch 1 not taken.
20 if (s) {
50
3/3
✓ Branch 1 taken 20 times.
✓ Branch 4 taken 20 times.
✓ Branch 7 taken 20 times.
20 airTerminal->setName(s.get());
51 }
52
53
1/1
✓ Branch 1 taken 20 times.
20 s = workspaceObject.getString(AirTerminal_SingleDuct_ConstantVolume_NoReheatFields::MaximumAirFlowRate);
54
8/17
✓ Branch 1 taken 20 times.
✗ Branch 2 not taken.
✓ Branch 4 taken 20 times.
✓ Branch 7 taken 20 times.
✓ Branch 10 taken 20 times.
✓ Branch 12 taken 20 times.
✗ Branch 13 not taken.
✓ Branch 14 taken 20 times.
✗ Branch 15 not taken.
✓ Branch 17 taken 20 times.
✗ Branch 18 not taken.
✓ Branch 19 taken 20 times.
✗ Branch 20 not taken.
✗ Branch 21 not taken.
✗ Branch 22 not taken.
✗ Branch 24 not taken.
✗ Branch 25 not taken.
80 if (s && istringEqual(s.get(), "AutoSize")) {
55
2/2
✓ Branch 1 taken 20 times.
✓ Branch 4 taken 20 times.
20 airTerminal->autosizeMaximumAirFlowRate();
56 ✗ } else if ((value = workspaceObject.getDouble(AirTerminal_SingleDuct_ConstantVolume_NoReheatFields::MaximumAirFlowRate))) {
57 ✗ airTerminal->setMaximumAirFlowRate(value.get());
58 }
59
60
2/2
✓ Branch 1 taken 20 times.
✓ Branch 4 taken 20 times.
20 return airTerminal.get();
61 20 } else {
62 ✗ LOG(Error, "Unknown error translating " << workspaceObject.briefDescription());
63
64 ✗ return boost::none;
65 }
66 20 }
67
68 } // namespace energyplus
69
70 } // namespace openstudio
71