GCC Code Coverage Report


Directory: ./
Coverage: low: ≥ 0% medium: ≥ 75.0% high: ≥ 90.0%
Coverage Exec / Excl / Total
Lines: 70.9% 61 / 0 / 86
Functions: 100.0% 1 / 0 / 1
Branches: 52.8% 105 / 0 / 199

src/energyplus/ReverseTranslator/ReverseTranslateEnergyManagementSystemMeteredOutputVariable.cpp
Line Branch Exec Source
1 /***********************************************************************************************************************
2 * OpenStudio(R), Copyright (c) Alliance for Energy Innovation, LLC.
3 * See also https://openstudio.net/license
4 ***********************************************************************************************************************/
5
6 #include "../ReverseTranslator.hpp"
7
8 #include "../../model/EnergyManagementSystemMeteredOutputVariable.hpp"
9 #include "../../model/EnergyManagementSystemMeteredOutputVariable_Impl.hpp"
10 #include "../../model/EnergyManagementSystemProgram.hpp"
11 #include "../../model/EnergyManagementSystemProgram_Impl.hpp"
12 #include "../../model/EnergyManagementSystemSubroutine.hpp"
13 #include "../../model/EnergyManagementSystemSubroutine_Impl.hpp"
14 #include "../../model/EnergyManagementSystemGlobalVariable.hpp"
15 #include "../../model/EnergyManagementSystemGlobalVariable_Impl.hpp"
16
17 #include <utilities/idd/EnergyManagementSystem_MeteredOutputVariable_FieldEnums.hxx>
18 #include "../../utilities/idd/IddEnums.hpp"
19 #include <utilities/idd/IddEnums.hxx>
20
21 using namespace openstudio::model;
22
23 namespace openstudio {
24
25 namespace energyplus {
26
27 1 OptionalModelObject ReverseTranslator::translateEnergyManagementSystemMeteredOutputVariable(const WorkspaceObject& workspaceObject) {
28
4/5
✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 7 taken 1 time.
✗ Branch 11 not taken.
✓ Branch 12 taken 1 time.
1 if (workspaceObject.iddObject().type() != IddObjectType::EnergyManagementSystem_MeteredOutputVariable) {
29 ✗ LOG(Error, "WorkspaceObject is not IddObjectType: EnergyManagementSystem_MeteredOutputVariable");
30 ✗ return boost::none;
31 }
32
33 //make sure all other objects are translated first except below
34
3/3
✓ Branch 1 taken 1 time.
✓ Branch 8 taken 29 times.
✓ Branch 9 taken 1 time.
30 for (const WorkspaceObject& workspaceObject : m_workspace.objects()) {
35
4/6
✓ Branch 1 taken 29 times.
✓ Branch 4 taken 29 times.
✓ Branch 8 taken 26 times.
✓ Branch 9 taken 3 times.
✗ Branch 10 not taken.
✗ Branch 11 not taken.
58 if ((workspaceObject.iddObject().type() != IddObjectType::EnergyManagementSystem_Program)
36
6/9
✓ Branch 1 taken 28 times.
✓ Branch 4 taken 28 times.
✓ Branch 7 taken 28 times.
✓ Branch 10 taken 27 times.
✓ Branch 11 taken 1 time.
✓ Branch 13 taken 29 times.
✗ Branch 14 not taken.
✗ Branch 15 not taken.
✗ Branch 16 not taken.
57 && (workspaceObject.iddObject().type() != IddObjectType::EnergyManagementSystem_Subroutine)
37
6/9
✓ Branch 1 taken 27 times.
✓ Branch 4 taken 27 times.
✓ Branch 7 taken 27 times.
✓ Branch 10 taken 27 times.
✗ Branch 11 not taken.
✓ Branch 13 taken 28 times.
✓ Branch 14 taken 1 time.
✗ Branch 15 not taken.
✗ Branch 16 not taken.
56 && (workspaceObject.iddObject().type() != IddObjectType::EnergyManagementSystem_ProgramCallingManager)
38
7/9
✓ Branch 1 taken 27 times.
✓ Branch 4 taken 27 times.
✓ Branch 7 taken 27 times.
✓ Branch 10 taken 26 times.
✓ Branch 11 taken 1 time.
✓ Branch 13 taken 27 times.
✓ Branch 14 taken 2 times.
✗ Branch 15 not taken.
✗ Branch 16 not taken.
56 && (workspaceObject.iddObject().type() != IddObjectType::EnergyManagementSystem_MeteredOutputVariable)
39
11/14
✓ Branch 1 taken 29 times.
✓ Branch 3 taken 28 times.
✓ Branch 4 taken 1 time.
✓ Branch 6 taken 26 times.
✓ Branch 9 taken 26 times.
✓ Branch 12 taken 26 times.
✓ Branch 15 taken 26 times.
✗ Branch 16 not taken.
✓ Branch 17 taken 26 times.
✓ Branch 18 taken 3 times.
✓ Branch 20 taken 27 times.
✓ Branch 21 taken 2 times.
✗ Branch 22 not taken.
✗ Branch 23 not taken.
86 && (workspaceObject.iddObject().type() != IddObjectType::EnergyManagementSystem_OutputVariable)) {
40
1/1
✓ Branch 1 taken 26 times.
26 translateAndMapWorkspaceObject(workspaceObject);
41 }
42 1 }
43
44
1/1
✓ Branch 1 taken 1 time.
1 OptionalString s = workspaceObject.getString(EnergyManagementSystem_MeteredOutputVariableFields::Name);
45
1/2
✗ Branch 1 not taken.
✓ Branch 2 taken 1 time.
1 if (!s) {
46 ✗ LOG(Error, "WorkspaceObject EnergyManagementSystem_MeteredOutputVariable has no Name");
47 ✗ return boost::none;
48 }
49
1/1
✓ Branch 1 taken 1 time.
1 openstudio::model::EnergyManagementSystemMeteredOutputVariable emsOutputVariable(m_model);
50
2/2
✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
1 emsOutputVariable.setName(*s);
51
52
1/1
✓ Branch 1 taken 1 time.
1 s = workspaceObject.getString(EnergyManagementSystem_MeteredOutputVariableFields::UpdateFrequency);
53
1/2
✗ Branch 1 not taken.
✓ Branch 2 taken 1 time.
1 if (!s) {
54 ✗ LOG(Error, emsOutputVariable.nameString() + ": UpdateFrequency not set");
55 ✗ return boost::none;
56 } else {
57
2/2
✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
1 emsOutputVariable.setUpdateFrequency(*s);
58 }
59
60
1/1
✓ Branch 1 taken 1 time.
1 s = workspaceObject.getString(EnergyManagementSystem_MeteredOutputVariableFields::ResourceType);
61
1/2
✗ Branch 1 not taken.
✓ Branch 2 taken 1 time.
1 if (!s) {
62 ✗ LOG(Error, emsOutputVariable.nameString() + ": ResourceType not set");
63 ✗ return boost::none;
64 } else {
65
2/2
✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
1 emsOutputVariable.setResourceType(*s);
66 }
67
68
1/1
✓ Branch 1 taken 1 time.
1 s = workspaceObject.getString(EnergyManagementSystem_MeteredOutputVariableFields::GroupType);
69
1/2
✗ Branch 1 not taken.
✓ Branch 2 taken 1 time.
1 if (!s) {
70 ✗ LOG(Error, emsOutputVariable.nameString() + ": GroupType not set");
71 ✗ return boost::none;
72 } else {
73
2/2
✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
1 emsOutputVariable.setGroupType(*s);
74 }
75
76
1/1
✓ Branch 1 taken 1 time.
1 s = workspaceObject.getString(EnergyManagementSystem_MeteredOutputVariableFields::EndUseCategory);
77
1/2
✗ Branch 1 not taken.
✓ Branch 2 taken 1 time.
1 if (!s) {
78 ✗ LOG(Error, emsOutputVariable.nameString() + ": EndUseCategory not set");
79 ✗ return boost::none;
80 } else {
81
2/2
✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
1 emsOutputVariable.setEndUseCategory(*s);
82 }
83
84
1/1
✓ Branch 1 taken 1 time.
1 s = workspaceObject.getString(EnergyManagementSystem_MeteredOutputVariableFields::EndUseSubcategory);
85
1/2
✓ Branch 0 taken 1 time.
✗ Branch 1 not taken.
1 if (s) {
86
2/2
✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
1 emsOutputVariable.setEndUseSubcategory(*s);
87 }
88
89
1/1
✓ Branch 1 taken 1 time.
1 s = workspaceObject.getString(EnergyManagementSystem_MeteredOutputVariableFields::Units);
90
1/2
✓ Branch 0 taken 1 time.
✗ Branch 1 not taken.
1 if (s) {
91
2/2
✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
1 emsOutputVariable.setUnits(*s);
92 }
93
94
1/1
✓ Branch 1 taken 1 time.
1 s = workspaceObject.getString(EnergyManagementSystem_MeteredOutputVariableFields::EMSProgramorSubroutineName);
95
1/2
✓ Branch 0 taken 1 time.
✗ Branch 1 not taken.
1 if (s) {
96
1/1
✓ Branch 1 taken 1 time.
1 Workspace workspace = workspaceObject.workspace();
97
3/4
✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 11 taken 1 time.
✗ Branch 12 not taken.
1 for (WorkspaceObject& wsObject : workspace.getObjectsByName(*s)) {
98
1/1
✓ Branch 1 taken 1 time.
1 boost::optional<model::ModelObject> modelObject = translateAndMapWorkspaceObject(wsObject);
99
1/2
✓ Branch 0 taken 1 time.
✗ Branch 1 not taken.
1 if (modelObject) {
100
4/5
✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 7 taken 1 time.
✗ Branch 10 not taken.
✓ Branch 11 taken 1 time.
1 if (modelObject.get().iddObjectType() == IddObjectType::OS_EnergyManagementSystem_Program) {
101 ✗ auto program = modelObject.get().cast<EnergyManagementSystemProgram>();
102 ✗ emsOutputVariable.setEMSProgramOrSubroutineName(program);
103
4/5
✓ Branch 2 taken 1 time.
✓ Branch 5 taken 1 time.
✓ Branch 8 taken 1 time.
✓ Branch 11 taken 1 time.
✗ Branch 12 not taken.
1 } else if (modelObject.get().iddObjectType() == IddObjectType::OS_EnergyManagementSystem_Subroutine) {
104
2/2
✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
1 auto subroutine = modelObject.get().cast<EnergyManagementSystemSubroutine>();
105
1/1
✓ Branch 1 taken 1 time.
1 emsOutputVariable.setEMSProgramOrSubroutineName(subroutine);
106 1 }
107 1 break;
108 }
109 2 }
110 1 }
111
112
1/1
✓ Branch 1 taken 1 time.
1 s = workspaceObject.getString(EnergyManagementSystem_MeteredOutputVariableFields::EMSVariableName);
113
1/2
✗ Branch 1 not taken.
✓ Branch 2 taken 1 time.
1 if (!s) {
114 ✗ LOG(Error, emsOutputVariable.nameString() + ": EMSVariableName not set");
115 ✗ return boost::none;
116 } else {
117 1 bool result = false;
118
1/1
✓ Branch 1 taken 1 time.
1 Workspace workspace = workspaceObject.workspace();
119 //look for GlobalVariables, translate and check if there is a name match since GV's dont have name field.
120
3/4
✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✗ Branch 11 not taken.
✓ Branch 12 taken 1 time.
1 for (WorkspaceObject& wsObject : workspace.getObjectsByType(IddObjectType::EnergyManagementSystem_GlobalVariable)) {
121 ✗ boost::optional<model::ModelObject> modelObject = translateAndMapWorkspaceObject(wsObject);
122 ✗ if (modelObject) {
123 ✗ if (modelObject.get().cast<EnergyManagementSystemGlobalVariable>().name() == s) {
124 ✗ result = emsOutputVariable.setEMSVariableName(*s);
125 ✗ if (result) {
126 ✗ return emsOutputVariable;
127 } else {
128 ✗ return boost::none;
129 }
130 }
131 }
132 1 }
133 //look for name match on other (EMS) objects.
134
3/4
✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
✓ Branch 11 taken 1 time.
✗ Branch 12 not taken.
1 for (WorkspaceObject& wsObject : workspace.getObjectsByName(*s)) {
135
1/1
✓ Branch 1 taken 1 time.
1 boost::optional<model::ModelObject> modelObject = translateAndMapWorkspaceObject(wsObject);
136
1/2
✓ Branch 0 taken 1 time.
✗ Branch 1 not taken.
1 if (modelObject) {
137
2/2
✓ Branch 1 taken 1 time.
✓ Branch 4 taken 1 time.
1 result = emsOutputVariable.setEMSVariableName(*s);
138
1/2
✓ Branch 0 taken 1 time.
✗ Branch 1 not taken.
1 if (result) {
139
1/1
✓ Branch 1 taken 1 time.
1 return emsOutputVariable;
140 } else {
141 ✗ return boost::none;
142 }
143 }
144 2 }
145 1 }
146
147 ✗ return emsOutputVariable;
148 1 }
149
150 } // namespace energyplus
151
152 } // namespace openstudio
153