src/energyplus/ReverseTranslator/ReverseTranslateGeneratorMicroTurbine.cpp
| Line | Branch | Exec | Source |
|---|---|---|---|
| 1 | /*********************************************************************************************************************** | ||
| 2 | * OpenStudio(R), Copyright (c) Alliance for Energy Innovation, LLC. | ||
| 3 | * See also https://openstudio.net/license | ||
| 4 | ***********************************************************************************************************************/ | ||
| 5 | |||
| 6 | #include "../ReverseTranslator.hpp" | ||
| 7 | |||
| 8 | #include "../../model/GeneratorMicroTurbine.hpp" | ||
| 9 | #include "../../model/GeneratorMicroTurbine_Impl.hpp" | ||
| 10 | #include "../../model/GeneratorMicroTurbineHeatRecovery.hpp" | ||
| 11 | #include "../../model/GeneratorMicroTurbineHeatRecovery_Impl.hpp" | ||
| 12 | |||
| 13 | #include "../../model/Schedule.hpp" | ||
| 14 | #include "../../model/Schedule_Impl.hpp" | ||
| 15 | |||
| 16 | #include "../../model/Curve.hpp" | ||
| 17 | #include "../../model/Curve_Impl.hpp" | ||
| 18 | #include "../../model/CurveBicubic.hpp" | ||
| 19 | #include "../../model/CurveBicubic_Impl.hpp" | ||
| 20 | #include "../../model/CurveBiquadratic.hpp" | ||
| 21 | #include "../../model/CurveBiquadratic_Impl.hpp" | ||
| 22 | #include "../../model/CurveCubic.hpp" | ||
| 23 | #include "../../model/CurveCubic_Impl.hpp" | ||
| 24 | #include "../../model/CurveQuadratic.hpp" | ||
| 25 | #include "../../model/CurveQuadratic_Impl.hpp" | ||
| 26 | |||
| 27 | #include <utilities/idd/Generator_MicroTurbine_FieldEnums.hxx> | ||
| 28 | //#include <utilities/idd/Generator_MicroTurbine_HeatRecoveryFieldEnums.hxx> | ||
| 29 | #include "../../utilities/idd/IddEnums.hpp" | ||
| 30 | #include <utilities/idd/IddEnums.hxx> | ||
| 31 | |||
| 32 | using namespace openstudio::model; | ||
| 33 | |||
| 34 | namespace openstudio { | ||
| 35 | |||
| 36 | namespace energyplus { | ||
| 37 | |||
| 38 | 2 | OptionalModelObject ReverseTranslator::translateGeneratorMicroTurbine(const WorkspaceObject& workspaceObject) { | |
| 39 | |||
| 40 | 2 | OptionalModelObject result; | |
| 41 | 2 | OptionalModelObject temp; | |
| 42 | 2 | OptionalDouble d; | |
| 43 | 2 | boost::optional<WorkspaceObject> owo; | |
| 44 | 2 | OptionalString optS; | |
| 45 | |||
| 46 | // TODO: The availability schedule is in the ElectricLoadCenter:Generators (list) in E+, here it's carried by the generator itself | ||
| 47 | // Should also get the Rated Thermal To Electrical Power Ratio in the list | ||
| 48 | |||
| 49 | //Generator:MicroTurbine, | ||
| 50 | // Capstone C65, !- Name | ||
| 51 | |||
| 52 |
1/1✓ Branch 1 taken 2 times.
|
2 | openstudio::model::GeneratorMicroTurbine mchp(m_model); |
| 53 | |||
| 54 | // Name | ||
| 55 |
1/1✓ Branch 1 taken 2 times.
|
2 | optS = workspaceObject.name(); |
| 56 |
1/2✓ Branch 0 taken 2 times.
✗ Branch 1 not taken.
|
2 | if (optS) { |
| 57 |
2/2✓ Branch 1 taken 2 times.
✓ Branch 4 taken 2 times.
|
2 | mchp.setName(*optS); |
| 58 | } | ||
| 59 | |||
| 60 | // 65000, !- Reference Electrical Power Output {W} | ||
| 61 |
1/1✓ Branch 1 taken 2 times.
|
2 | d = workspaceObject.getDouble(Generator_MicroTurbineFields::ReferenceElectricalPowerOutput); |
| 62 |
1/2✗ Branch 0 not taken.
✓ Branch 1 taken 2 times.
|
2 | if (d) { |
| 63 | ✗ | mchp.setReferenceElectricalPowerOutput(*d); | |
| 64 | } | ||
| 65 | // 29900, !- Minimum Full Load Electrical Power Output {W} | ||
| 66 |
1/1✓ Branch 1 taken 2 times.
|
2 | d = workspaceObject.getDouble(Generator_MicroTurbineFields::MinimumFullLoadElectricalPowerOutput); |
| 67 |
1/2✗ Branch 0 not taken.
✓ Branch 1 taken 2 times.
|
2 | if (d) { |
| 68 | ✗ | mchp.setMinimumFullLoadElectricalPowerOutput(*d); | |
| 69 | } | ||
| 70 | // 65000, !- Maximum Full Load Electrical Power Output {W} setMaximumFullLoadElectricalPowerOutput | ||
| 71 |
1/1✓ Branch 1 taken 2 times.
|
2 | d = workspaceObject.getDouble(Generator_MicroTurbineFields::MaximumFullLoadElectricalPowerOutput); |
| 72 |
1/2✗ Branch 0 not taken.
✓ Branch 1 taken 2 times.
|
2 | if (d) { |
| 73 | ✗ | mchp.setMaximumFullLoadElectricalPowerOutput(*d); | |
| 74 | } | ||
| 75 | |||
| 76 | // 0.29, !- Reference Electrical Efficiency Using Lower Heating Value | ||
| 77 |
1/1✓ Branch 1 taken 2 times.
|
2 | d = workspaceObject.getDouble(Generator_MicroTurbineFields::ReferenceElectricalEfficiencyUsingLowerHeatingValue); |
| 78 |
1/2✗ Branch 0 not taken.
✓ Branch 1 taken 2 times.
|
2 | if (d) { |
| 79 | ✗ | mchp.setReferenceElectricalEfficiencyUsingLowerHeatingValue(*d); | |
| 80 | } | ||
| 81 | |||
| 82 | // 15.0, !- Reference Combustion Air Inlet Temperature {C} | ||
| 83 |
1/1✓ Branch 1 taken 2 times.
|
2 | d = workspaceObject.getDouble(Generator_MicroTurbineFields::ReferenceCombustionAirInletTemperature); |
| 84 |
1/2✗ Branch 0 not taken.
✓ Branch 1 taken 2 times.
|
2 | if (d) { |
| 85 | ✗ | mchp.setReferenceCombustionAirInletTemperature(*d); | |
| 86 | } | ||
| 87 | |||
| 88 | // 0.00638, !- Reference Combustion Air Inlet Humidity Ratio {kgWater/kgDryAir} | ||
| 89 |
1/1✓ Branch 1 taken 2 times.
|
2 | d = workspaceObject.getDouble(Generator_MicroTurbineFields::ReferenceCombustionAirInletHumidityRatio); |
| 90 |
1/2✗ Branch 0 not taken.
✓ Branch 1 taken 2 times.
|
2 | if (d) { |
| 91 | ✗ | mchp.setReferenceCombustionAirInletHumidityRatio(*d); | |
| 92 | } | ||
| 93 | |||
| 94 | // 0.0, !- Reference Elevation {m} | ||
| 95 |
1/1✓ Branch 1 taken 2 times.
|
2 | d = workspaceObject.getDouble(Generator_MicroTurbineFields::MinimumFullLoadElectricalPowerOutput); |
| 96 |
1/2✗ Branch 0 not taken.
✓ Branch 1 taken 2 times.
|
2 | if (d) { |
| 97 | ✗ | mchp.setMinimumFullLoadElectricalPowerOutput(*d); | |
| 98 | } | ||
| 99 | |||
| 100 | // Capstone C65 Power_vs_Temp_Elev, !- Electrical Power Function of Temperature and Elevation Curve Name | ||
| 101 | // BiquadraticCurves | ||
| 102 |
2/3✓ Branch 1 taken 2 times.
✗ Branch 5 not taken.
✓ Branch 6 taken 2 times.
|
4 | if ((owo = workspaceObject.getTarget(Generator_MicroTurbineFields::ElectricalPowerFunctionofTemperatureandElevationCurveName))) { |
| 103 | ✗ | if (boost::optional<ModelObject> mo = translateAndMapWorkspaceObject(owo.get())) { | |
| 104 | ✗ | if (boost::optional<CurveBiquadratic> curve = mo->optionalCast<CurveBiquadratic>()) { | |
| 105 | ✗ | mchp.setElectricalPowerFunctionofTemperatureandElevationCurve(curve.get()); | |
| 106 | } else { | ||
| 107 | ✗ | LOG(Warn, workspaceObject.briefDescription() | |
| 108 | << " has a wrong type curve for field Electrical Power Function of Temperature and Elevation Curve Name"); | ||
| 109 | ✗ | } | |
| 110 | ✗ | } | |
| 111 | } | ||
| 112 | |||
| 113 | // Capstone C65 Efficiency_vs_Temp, !- Electrical Efficiency Function of Temperature Curve Name | ||
| 114 | // QuadraticCubicCurves | ||
| 115 |
2/3✓ Branch 1 taken 2 times.
✗ Branch 5 not taken.
✓ Branch 6 taken 2 times.
|
4 | if ((owo = workspaceObject.getTarget(Generator_MicroTurbineFields::ElectricalEfficiencyFunctionofTemperatureCurveName))) { |
| 116 | ✗ | if (boost::optional<ModelObject> mo = translateAndMapWorkspaceObject(owo.get())) { | |
| 117 | ✗ | if (boost::optional<CurveQuadratic> curve = mo->optionalCast<CurveQuadratic>()) { | |
| 118 | ✗ | mchp.setElectricalEfficiencyFunctionofTemperatureCurve(curve.get()); | |
| 119 | ✗ | } else if (boost::optional<CurveCubic> curve = mo->optionalCast<CurveCubic>()) { | |
| 120 | ✗ | mchp.setElectricalEfficiencyFunctionofTemperatureCurve(curve.get()); | |
| 121 | } else { | ||
| 122 | ✗ | LOG(Warn, workspaceObject.briefDescription() | |
| 123 | << " has a wrong type curve for field Electrical Efficiency Function of Temperature Curve Name"); | ||
| 124 | ✗ | } | |
| 125 | ✗ | } | |
| 126 | } | ||
| 127 | |||
| 128 | // Capstone C65 Efficiency_vs_PLR, !- Electrical Efficiency Function of Part Load Ratio Curve Name | ||
| 129 | // QuadraticCubicCurves | ||
| 130 | // setElectricalEfficiencyFunctionofPartLoadRatioCurve | ||
| 131 |
2/3✓ Branch 1 taken 2 times.
✗ Branch 5 not taken.
✓ Branch 6 taken 2 times.
|
4 | if ((owo = workspaceObject.getTarget(Generator_MicroTurbineFields::ElectricalEfficiencyFunctionofPartLoadRatioCurveName))) { |
| 132 | ✗ | if (boost::optional<ModelObject> mo = translateAndMapWorkspaceObject(owo.get())) { | |
| 133 | ✗ | if (boost::optional<CurveQuadratic> curve = mo->optionalCast<CurveQuadratic>()) { | |
| 134 | ✗ | mchp.setElectricalEfficiencyFunctionofPartLoadRatioCurve(curve.get()); | |
| 135 | ✗ | } else if (boost::optional<CurveCubic> curve = mo->optionalCast<CurveCubic>()) { | |
| 136 | ✗ | mchp.setElectricalEfficiencyFunctionofPartLoadRatioCurve(curve.get()); | |
| 137 | } else { | ||
| 138 | ✗ | LOG(Warn, workspaceObject.briefDescription() | |
| 139 | << " has a wrong type curve for field Electrical Efficiency Function of Part Load Ratio Curve Name"); | ||
| 140 | ✗ | } | |
| 141 | ✗ | } | |
| 142 | } | ||
| 143 | |||
| 144 | // NaturalGas, !- Fuel Type | ||
| 145 |
1/1✓ Branch 1 taken 2 times.
|
2 | optS = workspaceObject.getString(Generator_MicroTurbineFields::FuelType); |
| 146 |
1/2✗ Branch 0 not taken.
✓ Branch 1 taken 2 times.
|
2 | if (optS) { |
| 147 | ✗ | mchp.setFuelType(*optS); | |
| 148 | } | ||
| 149 | |||
| 150 | // 50000, !- Fuel Higher Heating Value {kJ/kg} | ||
| 151 |
1/1✓ Branch 1 taken 2 times.
|
2 | d = workspaceObject.getDouble(Generator_MicroTurbineFields::FuelHigherHeatingValue); |
| 152 |
1/2✗ Branch 0 not taken.
✓ Branch 1 taken 2 times.
|
2 | if (d) { |
| 153 | ✗ | mchp.setFuelHigherHeatingValue(*d); | |
| 154 | } | ||
| 155 | |||
| 156 | // 45450, !- Fuel Lower Heating Value {kJ/kg} | ||
| 157 |
1/1✓ Branch 1 taken 2 times.
|
2 | d = workspaceObject.getDouble(Generator_MicroTurbineFields::FuelLowerHeatingValue); |
| 158 |
1/2✗ Branch 0 not taken.
✓ Branch 1 taken 2 times.
|
2 | if (d) { |
| 159 | ✗ | mchp.setFuelLowerHeatingValue(*d); | |
| 160 | } | ||
| 161 | |||
| 162 | // 300, !- Standby Power {W} | ||
| 163 |
1/1✓ Branch 1 taken 2 times.
|
2 | d = workspaceObject.getDouble(Generator_MicroTurbineFields::StandbyPower); |
| 164 |
1/2✗ Branch 0 not taken.
✓ Branch 1 taken 2 times.
|
2 | if (d) { |
| 165 | ✗ | mchp.setStandbyPower(*d); | |
| 166 | } | ||
| 167 | |||
| 168 | // 4500, !- Ancillary Power {W} | ||
| 169 |
1/1✓ Branch 1 taken 2 times.
|
2 | d = workspaceObject.getDouble(Generator_MicroTurbineFields::AncillaryPower); |
| 170 |
1/2✗ Branch 0 not taken.
✓ Branch 1 taken 2 times.
|
2 | if (d) { |
| 171 | ✗ | mchp.setAncillaryPower(*d); | |
| 172 | } | ||
| 173 | |||
| 174 | // , !- Ancillary Power Function of Fuel Input Curve Name | ||
| 175 | // QuadraticCurves | ||
| 176 | // mchp.setAncillaryPowerFunctionofFuelInputCurve | ||
| 177 |
2/3✓ Branch 1 taken 2 times.
✗ Branch 5 not taken.
✓ Branch 6 taken 2 times.
|
4 | if ((owo = workspaceObject.getTarget(Generator_MicroTurbineFields::AncillaryPowerFunctionofFuelInputCurveName))) { |
| 178 | ✗ | if (boost::optional<ModelObject> mo = translateAndMapWorkspaceObject(owo.get())) { | |
| 179 | ✗ | if (boost::optional<CurveQuadratic> curve = mo->optionalCast<CurveQuadratic>()) { | |
| 180 | ✗ | mchp.setAncillaryPowerFunctionofFuelInputCurve(curve.get()); | |
| 181 | } else { | ||
| 182 | ✗ | LOG(Warn, workspaceObject.briefDescription() << " has a wrong type curve for field Ancillary Power Function of Fuel Input Curve Name"); | |
| 183 | ✗ | } | |
| 184 | ✗ | } | |
| 185 | } | ||
| 186 | |||
| 187 | // Fields in between (in E+.idd) are moved at the end in the Heat Recovery section | ||
| 188 | |||
| 189 | // Capstone C65 Combustion Air Inlet Node, !- Combustion Air Inlet Node Name | ||
| 190 | // Capstone C65 Combustion Air Outlet Node, !- Combustion Air Outlet Node Name | ||
| 191 | |||
| 192 | // 0.489885, !- Reference Exhaust Air Mass Flow Rate {kg/s} | ||
| 193 |
1/1✓ Branch 1 taken 2 times.
|
2 | d = workspaceObject.getDouble(Generator_MicroTurbineFields::ReferenceExhaustAirMassFlowRate); |
| 194 |
1/2✗ Branch 0 not taken.
✓ Branch 1 taken 2 times.
|
2 | if (d) { |
| 195 | ✗ | mchp.setReferenceExhaustAirMassFlowRate(*d); | |
| 196 | } | ||
| 197 | |||
| 198 | // Capstone C65 ExhAirFlowRate_vs_InletTemp, !- Exhaust Air Flow Rate Function of Temperature Curve Name | ||
| 199 | // QuadraticCubicCurves | ||
| 200 | // mchp.setExhaustAirFlowRateFunctionofTemperatureCurve | ||
| 201 |
2/3✓ Branch 1 taken 2 times.
✗ Branch 5 not taken.
✓ Branch 6 taken 2 times.
|
4 | if ((owo = workspaceObject.getTarget(Generator_MicroTurbineFields::ExhaustAirFlowRateFunctionofTemperatureCurveName))) { |
| 202 | ✗ | if (boost::optional<ModelObject> mo = translateAndMapWorkspaceObject(owo.get())) { | |
| 203 | ✗ | if (boost::optional<CurveQuadratic> curve = mo->optionalCast<CurveQuadratic>()) { | |
| 204 | ✗ | mchp.setExhaustAirFlowRateFunctionofTemperatureCurve(curve.get()); | |
| 205 | ✗ | } else if (boost::optional<CurveCubic> curve = mo->optionalCast<CurveCubic>()) { | |
| 206 | ✗ | mchp.setExhaustAirFlowRateFunctionofTemperatureCurve(curve.get()); | |
| 207 | } else { | ||
| 208 | ✗ | LOG(Warn, workspaceObject.briefDescription() | |
| 209 | << " has a wrong type curve for field Exhaust Air Flow Rate Function of Temperature Curve Name"); | ||
| 210 | ✗ | } | |
| 211 | ✗ | } | |
| 212 | } | ||
| 213 | |||
| 214 | // Capstone C65 ExhAirFlowRate_vs_PLR, !- Exhaust Air Flow Rate Function of Part Load Ratio Curve Name | ||
| 215 | // QuadraticCubicCurves | ||
| 216 | // mchp.setExhaustAirFlowRateFunctionofPartLoadRatioCurve(curve) | ||
| 217 |
2/3✓ Branch 1 taken 2 times.
✗ Branch 5 not taken.
✓ Branch 6 taken 2 times.
|
4 | if ((owo = workspaceObject.getTarget(Generator_MicroTurbineFields::ExhaustAirFlowRateFunctionofPartLoadRatioCurveName))) { |
| 218 | ✗ | if (boost::optional<ModelObject> mo = translateAndMapWorkspaceObject(owo.get())) { | |
| 219 | ✗ | if (boost::optional<CurveQuadratic> curve = mo->optionalCast<CurveQuadratic>()) { | |
| 220 | ✗ | mchp.setExhaustAirFlowRateFunctionofPartLoadRatioCurve(curve.get()); | |
| 221 | ✗ | } else if (boost::optional<CurveCubic> curve = mo->optionalCast<CurveCubic>()) { | |
| 222 | ✗ | mchp.setExhaustAirFlowRateFunctionofPartLoadRatioCurve(curve.get()); | |
| 223 | } else { | ||
| 224 | ✗ | LOG(Warn, workspaceObject.briefDescription() | |
| 225 | << " has a wrong type curve for field Exhaust Air Flow Rate Function of Part Load Ratio Curve Name"); | ||
| 226 | ✗ | } | |
| 227 | ✗ | } | |
| 228 | } | ||
| 229 | |||
| 230 | // 308.9, !- Nominal Exhaust Air Outlet Temperature | ||
| 231 |
1/1✓ Branch 1 taken 2 times.
|
2 | d = workspaceObject.getDouble(Generator_MicroTurbineFields::NominalExhaustAirOutletTemperature); |
| 232 |
1/2✗ Branch 0 not taken.
✓ Branch 1 taken 2 times.
|
2 | if (d) { |
| 233 | ✗ | mchp.setNominalExhaustAirOutletTemperature(*d); | |
| 234 | } | ||
| 235 | |||
| 236 | // Capstone C65 ExhaustTemp_vs_InletTemp, !- Exhaust Air Temperature Function of Temperature Curve Name | ||
| 237 | // QuadraticCubicCurves | ||
| 238 | // mchp.setExhaustAirTemperatureFunctionofTemperatureCurve(curve) | ||
| 239 |
2/3✓ Branch 1 taken 2 times.
✗ Branch 5 not taken.
✓ Branch 6 taken 2 times.
|
4 | if ((owo = workspaceObject.getTarget(Generator_MicroTurbineFields::ExhaustAirTemperatureFunctionofTemperatureCurveName))) { |
| 240 | ✗ | if (boost::optional<ModelObject> mo = translateAndMapWorkspaceObject(owo.get())) { | |
| 241 | ✗ | if (boost::optional<CurveQuadratic> curve = mo->optionalCast<CurveQuadratic>()) { | |
| 242 | ✗ | mchp.setExhaustAirTemperatureFunctionofTemperatureCurve(curve.get()); | |
| 243 | ✗ | } else if (boost::optional<CurveCubic> curve = mo->optionalCast<CurveCubic>()) { | |
| 244 | ✗ | mchp.setExhaustAirTemperatureFunctionofTemperatureCurve(curve.get()); | |
| 245 | } else { | ||
| 246 | ✗ | LOG(Warn, workspaceObject.briefDescription() | |
| 247 | << " has a wrong type curve for field Exhaust Air Temperature Function of Temperature Curve Name"); | ||
| 248 | ✗ | } | |
| 249 | ✗ | } | |
| 250 | } | ||
| 251 | |||
| 252 | // Capstone C65 ExhaustTemp_vs_PLR; !- Exhaust Air Temperature Function of Part Load Ratio Curve Name | ||
| 253 | // QuadraticCubicCurves | ||
| 254 | // mchp.setExhaustAirTemperatureFunctionofPartLoadRatioCurve(curve) | ||
| 255 |
2/3✓ Branch 1 taken 2 times.
✗ Branch 5 not taken.
✓ Branch 6 taken 2 times.
|
4 | if ((owo = workspaceObject.getTarget(Generator_MicroTurbineFields::ExhaustAirTemperatureFunctionofPartLoadRatioCurveName))) { |
| 256 | ✗ | if (boost::optional<ModelObject> mo = translateAndMapWorkspaceObject(owo.get())) { | |
| 257 | ✗ | if (boost::optional<CurveQuadratic> curve = mo->optionalCast<CurveQuadratic>()) { | |
| 258 | ✗ | mchp.setExhaustAirTemperatureFunctionofPartLoadRatioCurve(curve.get()); | |
| 259 | ✗ | } else if (boost::optional<CurveCubic> curve = mo->optionalCast<CurveCubic>()) { | |
| 260 | ✗ | mchp.setExhaustAirTemperatureFunctionofPartLoadRatioCurve(curve.get()); | |
| 261 | } else { | ||
| 262 | ✗ | LOG(Warn, workspaceObject.briefDescription() | |
| 263 | << " has a wrong type curve for field Exhaust Air Temperature Function of Part Load Ratio Curve Name"); | ||
| 264 | ✗ | } | |
| 265 | ✗ | } | |
| 266 | } | ||
| 267 | |||
| 268 | /// HEAT RECOVERY PORTION | ||
| 269 | |||
| 270 | // Would need to add that to the plantLoop reverse translator | ||
| 271 | // Capstone C65 Heat Recovery Water Inlet Node, !- Heat Recovery Water Inlet Node Name | ||
| 272 | // Capstone C65 Heat Recovery Water Outlet Node, !- Heat Recovery Water Outlet Node Name | ||
| 273 | |||
| 274 | // TODO: For now, I trigger the creation is the 'Reference Thermal Efficiency Using Lower Heat Value' is filled. | ||
| 275 | // TODO: I should trigger it based on the `Rated Thermal To Electrical Power Ratio in the list` in the ElectricLoadCenter:Generators (list) | ||
| 276 | // TODO: But in order to do that, the ElectricLoadCenter:Distribution & ElectricLoadCenter:Generators need to have a reverse translator | ||
| 277 | |||
| 278 | // 0.4975, !- Reference Thermal Efficiency Using Lower Heat Value | ||
| 279 |
1/1✓ Branch 1 taken 2 times.
|
2 | d = workspaceObject.getDouble(Generator_MicroTurbineFields::ReferenceThermalEfficiencyUsingLowerHeatValue); |
| 280 | |||
| 281 |
1/2✗ Branch 0 not taken.
✓ Branch 1 taken 2 times.
|
2 | if (d) { |
| 282 | |||
| 283 | // Create a GeneratorMicroTurbineHeatRecovery module, and assign it to the MicroTurbine | ||
| 284 | // I've Set the Name in the constructor | ||
| 285 | ✗ | openstudio::model::GeneratorMicroTurbineHeatRecovery mchpHR(m_model, mchp); | |
| 286 | |||
| 287 | // Assign the Reference Thermal Efficiency Using Lower Heat Value | ||
| 288 | ✗ | mchpHR.setReferenceThermalEfficiencyUsingLowerHeatValue(*d); | |
| 289 | |||
| 290 | // 60.0, !- Reference Inlet Water Temperature {C} | ||
| 291 | ✗ | d = workspaceObject.getDouble(Generator_MicroTurbineFields::ReferenceInletWaterTemperature); | |
| 292 | ✗ | if (d) { | |
| 293 | ✗ | mchpHR.setReferenceInletWaterTemperature(*d); | |
| 294 | } | ||
| 295 | |||
| 296 | // PlantControl, !- Heat Recovery Water Flow Operating Mode | ||
| 297 | ✗ | optS = workspaceObject.getString(Generator_MicroTurbineFields::HeatRecoveryWaterFlowOperatingMode); | |
| 298 | ✗ | if (optS) { | |
| 299 | ✗ | mchpHR.setHeatRecoveryWaterFlowOperatingMode(*optS); | |
| 300 | } | ||
| 301 | |||
| 302 | // 0.00252362, !- Reference Heat Recovery Water Flow Rate {m3/s} | ||
| 303 | ✗ | d = workspaceObject.getDouble(Generator_MicroTurbineFields::ReferenceHeatRecoveryWaterFlowRate); | |
| 304 | ✗ | if (d) { | |
| 305 | ✗ | mchpHR.setReferenceHeatRecoveryWaterFlowRate(*d); | |
| 306 | } | ||
| 307 | |||
| 308 | // , !- Heat Recovery Water Flow Rate Function of Temperature and Power Curve Name | ||
| 309 | // BiquadraticCurves | ||
| 310 | // mchpHR.setHeatRecoveryWaterFlowRateFunctionofTemperatureandPowerCurve(); | ||
| 311 | ✗ | if ((owo = workspaceObject.getTarget(Generator_MicroTurbineFields::HeatRecoveryWaterFlowRateFunctionofTemperatureandPowerCurveName))) { | |
| 312 | ✗ | if (boost::optional<ModelObject> mo = translateAndMapWorkspaceObject(owo.get())) { | |
| 313 | ✗ | if (boost::optional<CurveBiquadratic> curve = mo->optionalCast<CurveBiquadratic>()) { | |
| 314 | ✗ | mchpHR.setHeatRecoveryWaterFlowRateFunctionofTemperatureandPowerCurve(curve.get()); | |
| 315 | } else { | ||
| 316 | ✗ | LOG(Warn, workspaceObject.briefDescription() | |
| 317 | << " has a wrong type curve for field Heat Recovery Water Flow Rate Function of Temperature and Power Curve Name"); | ||
| 318 | ✗ | } | |
| 319 | ✗ | } | |
| 320 | } | ||
| 321 | |||
| 322 | // Capstone C65 ThermalEff_vs_Temp_Elev, !- Thermal Efficiency Function of Temperature and Elevation Curve Name | ||
| 323 | // BicubicBiquadraticCurves | ||
| 324 | // mchpHR.setThermalEfficiencyFunctionofTemperatureandElevationCurve(); | ||
| 325 | ✗ | if ((owo = workspaceObject.getTarget(Generator_MicroTurbineFields::ThermalEfficiencyFunctionofTemperatureandElevationCurveName))) { | |
| 326 | ✗ | if (boost::optional<ModelObject> mo = translateAndMapWorkspaceObject(owo.get())) { | |
| 327 | ✗ | if (boost::optional<CurveBicubic> curve = mo->optionalCast<CurveBicubic>()) { | |
| 328 | ✗ | mchpHR.setThermalEfficiencyFunctionofTemperatureandElevationCurve(curve.get()); | |
| 329 | ✗ | } else if (boost::optional<CurveBiquadratic> curve = mo->optionalCast<CurveBiquadratic>()) { | |
| 330 | ✗ | mchpHR.setThermalEfficiencyFunctionofTemperatureandElevationCurve(curve.get()); | |
| 331 | } else { | ||
| 332 | ✗ | LOG(Warn, workspaceObject.briefDescription() | |
| 333 | << " has a wrong type curve for field Thermal Efficiency Function of Temperature and Elevation Curve Name"); | ||
| 334 | ✗ | } | |
| 335 | ✗ | } | |
| 336 | } | ||
| 337 | |||
| 338 | // Capstone C65 HeatRecoveryRate_vs_PLR, !- Heat Recovery Rate Function of Part Load Ratio Curve Name | ||
| 339 | // QuadraticCubicCurves | ||
| 340 | // mchpHR.setHeatRecoveryRateFunctionofPartLoadRatioCurve(); | ||
| 341 | ✗ | if ((owo = workspaceObject.getTarget(Generator_MicroTurbineFields::HeatRecoveryRateFunctionofPartLoadRatioCurveName))) { | |
| 342 | ✗ | if (boost::optional<ModelObject> mo = translateAndMapWorkspaceObject(owo.get())) { | |
| 343 | ✗ | if (boost::optional<CurveQuadratic> curve = mo->optionalCast<CurveQuadratic>()) { | |
| 344 | ✗ | mchpHR.setHeatRecoveryRateFunctionofPartLoadRatioCurve(curve.get()); | |
| 345 | ✗ | } else if (boost::optional<CurveCubic> curve = mo->optionalCast<CurveCubic>()) { | |
| 346 | ✗ | mchpHR.setHeatRecoveryRateFunctionofPartLoadRatioCurve(curve.get()); | |
| 347 | } else { | ||
| 348 | ✗ | LOG(Warn, workspaceObject.briefDescription() | |
| 349 | << " has a wrong type curve for field Heat Recovery Rate Function of Part Load Ratio Curve Name"); | ||
| 350 | ✗ | } | |
| 351 | ✗ | } | |
| 352 | } | ||
| 353 | |||
| 354 | // Capstone C65 HeatRecoveryRate_vs_InletTemp, !- Heat Recovery Rate Function of Inlet Water Temperature Curve Name | ||
| 355 | // QuadraticCurves | ||
| 356 | // mchpHR.setHeatRecoveryRateFunctionofInletWaterTemperatureCurve(); | ||
| 357 | ✗ | if ((owo = workspaceObject.getTarget(Generator_MicroTurbineFields::HeatRecoveryRateFunctionofInletWaterTemperatureCurveName))) { | |
| 358 | ✗ | if (boost::optional<ModelObject> mo = translateAndMapWorkspaceObject(owo.get())) { | |
| 359 | ✗ | if (boost::optional<CurveQuadratic> curve = mo->optionalCast<CurveQuadratic>()) { | |
| 360 | ✗ | mchpHR.setHeatRecoveryRateFunctionofInletWaterTemperatureCurve(curve.get()); | |
| 361 | } else { | ||
| 362 | ✗ | LOG(Warn, workspaceObject.briefDescription() | |
| 363 | << " has a wrong type curve for field Heat Recovery Rate Function of Part Load Ratio Curve Name"); | ||
| 364 | ✗ | } | |
| 365 | ✗ | } | |
| 366 | } | ||
| 367 | |||
| 368 | // Capstone C65 HeatRecoveryRate_vs_WaterFlow, !- Heat Recovery Rate Function of Water Flow Rate Curve Name | ||
| 369 | // QuadraticCurves | ||
| 370 | // mchpHR.setHeatRecoveryRateFunctionofInletWaterFlowRateCurve(); | ||
| 371 | ✗ | if ((owo = workspaceObject.getTarget(Generator_MicroTurbineFields::HeatRecoveryRateFunctionofWaterFlowRateCurveName))) { | |
| 372 | ✗ | if (boost::optional<ModelObject> mo = translateAndMapWorkspaceObject(owo.get())) { | |
| 373 | ✗ | if (boost::optional<CurveQuadratic> curve = mo->optionalCast<CurveQuadratic>()) { | |
| 374 | ✗ | mchpHR.setHeatRecoveryRateFunctionofWaterFlowRateCurve(curve.get()); | |
| 375 | } else { | ||
| 376 | ✗ | LOG(Warn, workspaceObject.briefDescription() | |
| 377 | << " has a wrong type curve for field Heat Recovery Rate Function of Water Flow Rate Curve Name"); | ||
| 378 | ✗ | } | |
| 379 | ✗ | } | |
| 380 | } | ||
| 381 | |||
| 382 | // 0.001577263, !- Minimum Heat Recovery Water Flow Rate {m3/s} | ||
| 383 | ✗ | d = workspaceObject.getDouble(Generator_MicroTurbineFields::MinimumHeatRecoveryWaterFlowRate); | |
| 384 | ✗ | if (d) { | |
| 385 | ✗ | mchpHR.setMinimumHeatRecoveryWaterFlowRate(*d); | |
| 386 | } | ||
| 387 | |||
| 388 | // 0.003785432, !- Maximum Heat Recovery Water Flow Rate {m3/s} | ||
| 389 | ✗ | d = workspaceObject.getDouble(Generator_MicroTurbineFields::MaximumHeatRecoveryWaterFlowRate); | |
| 390 | ✗ | if (d) { | |
| 391 | ✗ | mchpHR.setMaximumHeatRecoveryWaterFlowRate(*d); | |
| 392 | } | ||
| 393 | |||
| 394 | // 82.2, !- Maximum Heat Recovery Water Temperature {C} | ||
| 395 | ✗ | d = workspaceObject.getDouble(Generator_MicroTurbineFields::MaximumHeatRecoveryWaterTemperature); | |
| 396 | ✗ | if (d) { | |
| 397 | ✗ | mchpHR.setMaximumHeatRecoveryWaterTemperature(*d); | |
| 398 | } | ||
| 399 | ✗ | } | |
| 400 | |||
| 401 |
1/1✓ Branch 1 taken 2 times.
|
2 | result = mchp; |
| 402 | 4 | return result; | |
| 403 | 2 | } | |
| 404 | |||
| 405 | } // namespace energyplus | ||
| 406 | |||
| 407 | } // namespace openstudio | ||
| 408 |